Web of Science: Immunosensing of C-reactive protein in pleural fluid using electrodeposited silver nanoparticles
| dc.contributor.author | Gelen, S.S. | |
| dc.contributor.author | Gokce, B. | |
| dc.contributor.author | Yazgan, I. | |
| dc.contributor.author | Saygili, E. | |
| dc.contributor.author | Goksel, T. | |
| dc.contributor.author | Odaci, D. | |
| dc.date.accessioned | 2025-11-07T06:42:54Z | |
| dc.date.issued | 2026.01.01 | |
| dc.description.abstract | C-reactive protein (CRP) is a member of the acute phase reactants. CRP is generally used as a biomarker of inflammation and tissue injury. Here, CRP detection is performed in pleural fluid caused by pleural effusion. For this aim, Anti-CRP was conjugated on silver nanoparticle (AgNP)-modified electrodes to prepare immunosensors. To carry out AgNP electrodeposition, a novel ligand, mannose 4-aminophenyl L-alanine (Man-4APA), was synthesized and characterized using NMR and MS analysis. Then, AgNPs were synthesized in the presence of Man-4APA. After that, AgNPs/P (Man-4APA) was formed by electrodeposition on the electrodes. The success of the coating of the surfaces with AgNPs/P (Man-4APA) was confirmed using SEM and EDS analysis. Covalent conjugation was carried out between the amine groups of AgNPs/P (Man-4APA) and the carboxyl groups of AntiCRP. The formation of the obtained amide bond was examined using XPS analysis. Using the designed AgNPs/P (Man-4APA)/Anti-CRP, the linear range for CRP was 0.5-100 ng/mL with a LOD of 0.38 ng/mL. After testing the effect of some potential interfering compounds on the current signal of AgNPs/P (Man-4APA)/Anti-CRP, the determination of CRP in pleural fluid collected from patients with pleural effusion was carried out successfully. | |
| dc.identifier.doi | 10.1016/j.talanta.2025.128931 | |
| dc.identifier.eissn | 1873-3573 | |
| dc.identifier.endpage | ||
| dc.identifier.issn | 0039-9140 | |
| dc.identifier.issue | ||
| dc.identifier.startpage | ||
| dc.identifier.uri | https://www.webofscience.com/api/gateway?GWVersion=2&SrcApp=dspace_ku&SrcAuth=WosAPI&KeyUT=WOS:001594438600001&DestLinkType=FullRecord&DestApp=WOS_CPL | |
| dc.identifier.uri | https://hdl.handle.net/20.500.12597/35265 | |
| dc.identifier.volume | 298 | |
| dc.identifier.wos | 001594438600001 | |
| dc.language.iso | en | |
| dc.relation.ispartof | TALANTA | |
| dc.rights | info:eu-repo/semantics/closedAccess | |
| dc.subject | Nanobiotechnology | |
| dc.subject | Silver nanoparticles | |
| dc.subject | Glyconanoparticles | |
| dc.subject | Pleural fluid | |
| dc.subject | CRP | |
| dc.title | Immunosensing of C-reactive protein in pleural fluid using electrodeposited silver nanoparticles | |
| dc.type | Article | |
| dspace.entity.type | Wos |