dc.description.abstract | Background: Accurate and rapid measurement of blood β-hydroxybutyrate (β-OHB) concentrations is critical to identify hyperketonemia in sheep. Objective: The objective of this study was to test the performance of Freestyle Optium Neo H and TaiDoc-TD4235 point-of-care (POC) devices for measuring blood β-OHB concentrations in sheep. Methods: Venous blood samples from 105 sheep were evaluated with Freestyle Optium Neo H and TaiDoc-TD4235 meters. A reference approach was the laboratory measurement of serum BHB concentrations using the Randox D-3 Hydroxybutyrate reagent kit. Data were analyzed using Passing- Bablok regression and Bland–Altman analysis. The diagnostic accuracy was assessed using serum β-OHB concentration at a cut-off value of 0.8 mmol/L. Results: Passing-Bablok regression analysis revealed an intercept of 0.066 (CI95: 0.018–0.125) and slope of 1.242 (CI95: 1.136–1.342) for Freestyle Optium Neo H. Intercept and slope values for the TaiDoc-TD4235 meter were 0.625 (CI95: 0.539–0.724) and 1.265 (CI95: 1.044–1.497), respectively. The Bland–Altman plot revealed a bias of 0.224 mmol/L and 0.737 mmol/L for Freestyle Optium Neo H and TaiDoc-TD4235 meters, respectively, compared with the reference method. Observed Total Error (TEobs) was 56.7% for the Freestyle Optium Neo H and 168.7% for the Taidoc-TD4235. The sensitivity and specificity for the Freestyle Optium Neo H were 100% and 80.9%, respectively, at the threshold of 0.8 mmol/L. The Taidoc-TD4235 demonstrated a sensitivity of 93.3% and specificity of 8.9% at the threshold of 0.8 mmol/L. Conclusions: Because of the large TEobs, the Freestyle Optium Neo H and TaiDoc-TD4235 meters should not be used to quantify blood β-OHB concentrations in sheep. | |
dc.identifier.doi | 10.1111/vcp.13223 | |
dc.identifier.issn | 2756382 | |
dc.identifier.pubmed | 36859602 | |
dc.identifier.scopus | 2-s2.0-85149377546 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12597/3925 | |
dc.relation.ispartof | Veterinary Clinical Pathology | |
dc.rights | false | |
dc.subject | bias | ewe | point-of-care device | pregnancy toxemia | sensitivity | specificity | |
dc.title | Evaluation of Freestyle Optium Neo H and TaiDoc-TD4235 point-of-care meters for measuring blood β-hydroxybutyrate concentration in sheep | |
dc.type | Article | |
dspace.entity.type | Scopus | |
person.affiliation.name | Kastamonu University | |
person.affiliation.name | Bingöl Üniversitesi | |
person.identifier.orcid | 0000-0002-2861-0236 | |
person.identifier.scopus-author-id | 57205741344 | |
person.identifier.scopus-author-id | 57447855300 | |
relation.isPublicationOfScopus | 11ef2c2d-ca89-4205-a11b-9bf428ddde64 | |
relation.isPublicationOfScopus.latestForDiscovery | 11ef2c2d-ca89-4205-a11b-9bf428ddde64 |