Scopus:
Evaluation of Freestyle Optium Neo H and TaiDoc-TD4235 point-of-care meters for measuring blood β-hydroxybutyrate concentration in sheep

dc.contributor.authorTümer K.C.
dc.contributor.authorKılınç M.A.
dc.date.accessioned2023-04-11T22:11:18Z
dc.date.accessioned2023-04-12T00:29:34Z
dc.date.available2023-04-11T22:11:18Z
dc.date.available2023-04-12T00:29:34Z
dc.date.issued2023-01-01
dc.description.abstractBackground: Accurate and rapid measurement of blood β-hydroxybutyrate (β-OHB) concentrations is critical to identify hyperketonemia in sheep. Objective: The objective of this study was to test the performance of Freestyle Optium Neo H and TaiDoc-TD4235 point-of-care (POC) devices for measuring blood β-OHB concentrations in sheep. Methods: Venous blood samples from 105 sheep were evaluated with Freestyle Optium Neo H and TaiDoc-TD4235 meters. A reference approach was the laboratory measurement of serum BHB concentrations using the Randox D-3 Hydroxybutyrate reagent kit. Data were analyzed using Passing- Bablok regression and Bland–Altman analysis. The diagnostic accuracy was assessed using serum β-OHB concentration at a cut-off value of 0.8 mmol/L. Results: Passing-Bablok regression analysis revealed an intercept of 0.066 (CI95: 0.018–0.125) and slope of 1.242 (CI95: 1.136–1.342) for Freestyle Optium Neo H. Intercept and slope values for the TaiDoc-TD4235 meter were 0.625 (CI95: 0.539–0.724) and 1.265 (CI95: 1.044–1.497), respectively. The Bland–Altman plot revealed a bias of 0.224 mmol/L and 0.737 mmol/L for Freestyle Optium Neo H and TaiDoc-TD4235 meters, respectively, compared with the reference method. Observed Total Error (TEobs) was 56.7% for the Freestyle Optium Neo H and 168.7% for the Taidoc-TD4235. The sensitivity and specificity for the Freestyle Optium Neo H were 100% and 80.9%, respectively, at the threshold of 0.8 mmol/L. The Taidoc-TD4235 demonstrated a sensitivity of 93.3% and specificity of 8.9% at the threshold of 0.8 mmol/L. Conclusions: Because of the large TEobs, the Freestyle Optium Neo H and TaiDoc-TD4235 meters should not be used to quantify blood β-OHB concentrations in sheep.
dc.identifier.doi10.1111/vcp.13223
dc.identifier.issn2756382
dc.identifier.pubmed36859602
dc.identifier.scopus2-s2.0-85149377546
dc.identifier.urihttps://hdl.handle.net/20.500.12597/3925
dc.relation.ispartofVeterinary Clinical Pathology
dc.rightsfalse
dc.subjectbias | ewe | point-of-care device | pregnancy toxemia | sensitivity | specificity
dc.titleEvaluation of Freestyle Optium Neo H and TaiDoc-TD4235 point-of-care meters for measuring blood β-hydroxybutyrate concentration in sheep
dc.typeArticle
dspace.entity.typeScopus
person.affiliation.nameKastamonu University
person.affiliation.nameBingöl Üniversitesi
person.identifier.orcid0000-0002-2861-0236
person.identifier.scopus-author-id57205741344
person.identifier.scopus-author-id57447855300
relation.isPublicationOfScopus11ef2c2d-ca89-4205-a11b-9bf428ddde64
relation.isPublicationOfScopus.latestForDiscovery11ef2c2d-ca89-4205-a11b-9bf428ddde64

Files