| dc.description.abstract | This study aimed to compare thickness of the capsule, corium, and soft tissues measured ultrasonographically and macroscopically in selected regions of bovine claws. A hundred and twenty claws (n = 120) of 15 healthy Holstein bovines were obtained. After cleaning the claws, ultrasonographic measurement of the capsule, corium, and soft tissues was performed while submerging the claws in a water bath. Macroscopic measurements were taken after cutting of the claws axially. These values were compared statistically. According to the macroscopic measurements, the mean thickness ± standard deviation (SD) of the capsule for dorsal wall and sole was 6.2 ± 0.1 and 9.5 ± 0.4 mm, respectively. The thickness of the corium and soft tissues for dorsal wall and sole was 4.5 ± 0.1 and 5.3 ± 0.1 mm, respectively. Ultrasonographically, the mean thickness ± SD of the capsule for dorsal wall and sole was 4.7 ± 0.1 and 7.8 ± 0.3 mm, respectively. The thickness of the corium and soft tissues for dorsal wall and sole was 4.3 ± 0.1 and 5.9 ± 0.2 mm, respectively. Findings demonstrated that ultrasonography can be reliably to measure of the thickness of the hoof capsule, corium, and soft tissue in bovine claw. | |
| dc.identifier.doi | 10.4142/jvs.2015.16.1.107 | |
| dc.identifier.issn | 1229845X | |
| dc.identifier.pubmed | 25269721 | |
| dc.identifier.scopus | 2-s2.0-84928538296 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.12597/5830 | |
| dc.relation.ispartof | Journal of Veterinary Science | |
| dc.rights | true | |
| dc.subject | Bovine claw | Ultrasound | |
| dc.title | Ultrasonographic and macroscopic comparison of the thickness of the capsule, corium, and soft tissues in bovine claws: An in vitro study | |
| dc.type | Article | |
| dspace.entity.type | Scopus | |
| local.indexed.at | PubMed | |
| local.indexed.at | Scopus | |
| oaire.citation.issue | 1 | |
| oaire.citation.volume | 16 | |
| person.affiliation.name | Bursa Uludağ Üniversitesi | |
| person.affiliation.name | Bursa Uludağ Üniversitesi | |
| person.affiliation.name | Bursa Uludağ Üniversitesi | |
| person.affiliation.name | Bursa Uludağ Üniversitesi | |
| person.affiliation.name | Kastamonu University | |
| person.identifier.scopus-author-id | 16041418200 | |
| person.identifier.scopus-author-id | 8680329000 | |
| person.identifier.scopus-author-id | 24759148000 | |
| person.identifier.scopus-author-id | 8680328800 | |
| person.identifier.scopus-author-id | 24334005700 | |
| relation.isPublicationOfScopus | 6ae4281a-6bc2-422e-8584-c8a8fb278071 | |
| relation.isPublicationOfScopus.latestForDiscovery | 6ae4281a-6bc2-422e-8584-c8a8fb278071 |