Scopus:
Using indoor plants as biomonitors for detection of toxic metals by tobacco smoke

dc.contributor.authorGhoma W.E.O.
dc.contributor.authorSevik H.
dc.contributor.authorIsinkaralar K.
dc.date.accessioned2023-04-11T22:32:28Z
dc.date.accessioned2023-04-12T00:29:38Z
dc.date.available2023-04-11T22:32:28Z
dc.date.available2023-04-12T00:29:38Z
dc.date.issued2022-03-01
dc.description.abstractClean air is an indispensable resource for modern world. Many people are indifferent to the seriousness of air pollution or have only recently realized the problem. The air pollution continues deteriorating with several emissions every year on global scale. Beside various sources, tobacco smoke has caused the indoor air pollution. One of the most important of these factors is smoking. Especially indoor air pollution occurs depending on tobacco use. Exposure to cigarette smoke is recognized as the most significant health problem in indoor air. The study aims to evaluate the toxic metal accumulation due to tobacco smoke indoors by using some indoor ornamental plants. In this study, Dieffenbachia amoena, Dracena marginata, Ficus elastica, Spathiphyllum wallisii, and Yucca massengena were used houseplants as biomonitors. Accumulation of some toxic metals can be easily seen in indoor plants. Cadmium (Cd), chrome (Cr), and lead (Pb) were selected that high emissions from tobacco smoke. They were determined by taking the leaves of the plant species and analyzed with inductively coupled plasma-optical emission spectrometry (ICP-OES). The Cd, Cr, and Pb concentrations (Pb > Cr > Cd) were higher with tobacco than non-tobacco in all species. The results showed that Spathiphyllum wallisii was selected to be most suitable as biomonitor.
dc.identifier.doi10.1007/s11869-021-01146-z
dc.identifier.issn18739318
dc.identifier.scopus2-s2.0-85123464666
dc.identifier.urihttps://hdl.handle.net/20.500.12597/3970
dc.relation.ispartofAir Quality, Atmosphere and Health
dc.rightsfalse
dc.subjectBiomonitors | Indoor air pollution | Indoor plants | Tobacco use | Toxic metals
dc.titleUsing indoor plants as biomonitors for detection of toxic metals by tobacco smoke
dc.typeArticle
dspace.entity.typeScopus
oaire.citation.issue3
oaire.citation.volume15
person.affiliation.nameKastamonu University
person.affiliation.nameKastamonu University
person.affiliation.nameKastamonu University
person.identifier.orcid0000-0003-1850-7515
person.identifier.scopus-author-id57426644900
person.identifier.scopus-author-id36633291300
person.identifier.scopus-author-id57194029489
relation.isPublicationOfScopusd9db9420-03a6-41dc-a213-ffac2275a0b6
relation.isPublicationOfScopus.latestForDiscoveryd9db9420-03a6-41dc-a213-ffac2275a0b6

Files