dc.description.abstractIn scope of the study, behavior of timber-framed shear walls having openings with variable dimensions and locations subjected to reverse cyclic loading is experimentally investigated. Main variables considered in the study are the aspect ratios of timber-framed panel walls, dimensions and locations of the openings on the panel walls, material of the timber frames and spacings of the nails used in the panel connections. Load–displacement relationships, strengths, stiffnesses, displacement ductility ratios, energy dissipation capacities and failure mechanisms of the specimens are determined. The ultimate load capacities of the timber-framed panels are calculated as per Eurocode 5 and presented in comparison to experimental results. Moreover, lateral load-resisting capacities and load–displacement relationships of the test specimens are numerically calculated with finite element analyses. A good agreement was observed between the numerical and experimental results. From the test results, it is observed that the load behavior relationships of the test specimens significantly affected by aspect ratios, location of the openings, material of the timber frames and spacing of the nails used to provide connection between the timber-framed panel elements. Also, the increasing size of the openings decreased the stiffness’ of the test specimens.
dc.identifier.doi10.1007/s40999-016-0138-7
dc.identifier.issn17350522
dc.identifier.scopus2-s2.0-85047492255
dc.identifier.urihttps://hdl.handle.net/20.500.12597/5286
dc.relation.ispartofInternational Journal of Civil Engineering
dc.rightsfalse
dc.subjectCyclic load | Finite element analysis | Hysteretic behavior | Opening | Timber-framed shear wall
dc.titleEffect of Timber Type and Nail Spacing on the Hysteretic Behavior of Timber-Framed Shear Walls with Openings
dc.typeArticle
dspace.entity.typeScopus
oaire.citation.issue6
oaire.citation.volume16
person.affiliation.nameGazi Üniversitesi
person.affiliation.nameGazi Üniversitesi
person.affiliation.nameKastamonu University
person.affiliation.nameGazi Üniversitesi
person.affiliation.nameGazi Üniversitesi
person.identifier.scopus-author-id6508251680
person.identifier.scopus-author-id24172058500
person.identifier.scopus-author-id57189260675
person.identifier.scopus-author-id26656579200
person.identifier.scopus-author-id57202213604
relation.isPublicationOfScopus10378ee0-4593-439a-ad81-c27e8b4b9bb5
relation.isPublicationOfScopus.latestForDiscovery10378ee0-4593-439a-ad81-c27e8b4b9bb5

Files