Scopus:
Turbulent thermal-magneto convection in a teardrop-shaped dimpled tube: An experimental and numerical study

dc.contributor.authorDağdeviren, A.
dc.contributor.authorGürsoy, E.
dc.contributor.authorGürdal, M.
dc.contributor.authorGedik, E.
dc.contributor.authorArslan, K.
dc.date.accessioned2025-11-20T17:30:23Z
dc.date.issued2026
dc.description.abstractIn this study, the forced convection properties of teardrop-shaped dimpled fins, Fe 3 O 4 /H 2 O ferrofluid, and constant magnetic field parameters were investigated numerically and experimentally. The study consists of two parts. In the first part, a numerical simulation was conducted, incorporating all relevant parameters, and the results were analyzed. In the second part, the experimental setup was completed for the scenario that yields the highest performance evaluation criterion value, as determined from the numerical results. The Reynolds number (10000≤ Re ≤ 50000), the size of the teardrop-shaped dimple ( BTD , MTD and STD ), dimples distance (30≤ P ≤ 50), constant heat flux ( qʺ = 20 kW/m2), ferrofluid concentration ratio (0.0≤ φ vol. ≤2.0) and the constant magnetic field strength applied at x/D = 20 location (0 T ≤ B 0 ≤ 0.3 T) were studied experimentally and numerically. The findings showed that the DT9 case increased the thermal performance change by 36.18 % compared to the smooth tube. The highest heat transfer rate occurred in the magnetic field strength B 0 = 0.3 T. The magnetic field strength caused an improvement in heat transfer of 5.12 % and 7.32 % in the Nusselt number, respectively, in the numerical and experimental results. The highest PEC was obtained by using φ vol. = 2.0 % Fe3O4/H2O nanofluid in case DT9 ( STD , P = 50 mm) at Re = 10000 and B 0 = 0.3 T, with a contribution of 32.45 % compared to the smooth tube. The compound effect amounts of teardrop-shaped dimples, ferrofluid, and constant magnetic field were obtained numerically and experimentally as 55.41 % and 55.37 % in Nusselt number, while obtained as 29.15 % and 32.45 % in PEC , respectively, compared to a smooth tube, using H2O and the absence of a constant magnetic field.
dc.identifier10.1016/j.ijthermalsci.2025.110403
dc.identifier.doi10.1016/j.ijthermalsci.2025.110403
dc.identifier.issn12900729
dc.identifier.scopus2-s2.0-105020915604
dc.identifier.urihttps://hdl.handle.net/20.500.12597/35293
dc.identifier.volume220
dc.language.isoen
dc.publisherElsevier Masson s.r.l.
dc.relation.ispartofInternational Journal of Thermal Sciences
dc.relation.ispartofseriesInternational Journal of Thermal Sciences
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectDimpled fin | Ferrofluid | Magnetic field | Performance evaluation criterion | Teardrop dimple
dc.titleTurbulent thermal-magneto convection in a teardrop-shaped dimpled tube: An experimental and numerical study
dc.typearticle
dspace.entity.typeScopus
oaire.citation.volume220
person.affiliation.nameKarabük Üniversitesi
person.affiliation.nameKarabük Üniversitesi
person.affiliation.nameKarabük Üniversitesi
person.affiliation.nameKarabük Üniversitesi
person.affiliation.nameKarabük Üniversitesi
person.identifier.orcid0000-0002-5418-4445
person.identifier.orcid0000-0003-2373-3357
person.identifier.orcid0000-0003-2209-3394
person.identifier.scopus-author-id57219161996
person.identifier.scopus-author-id57893728200
person.identifier.scopus-author-id57204779331
person.identifier.scopus-author-id24472852700
person.identifier.scopus-author-id24478639200