Pubmed:
Predicting alternate light absorption in areas of trauma based on degree of skin pigmentation: Not all wavelengths are equal.

dc.contributor.authorScafide, Katherine N
dc.contributor.authorDowning, Nancy R
dc.contributor.authorKutahyalioglu, Nesibe S
dc.contributor.authorSheridan, Daniel J
dc.contributor.authorLanglois, Neil E
dc.contributor.authorHayat, Matthew J
dc.date.accessioned2023-04-06T22:47:09Z
dc.date.available2023-04-06T22:47:09Z
dc.date.issued2022-10-01T00:00:00Z
dc.description.abstractDetection and documentation of bruises on survivors of intimate partner violence (IPV) can provide valuable evidence to support investigation and subsequent prosecution of these crimes. Detection of bruises in persons with darker skin tones is often difficult, contributing to disparities in health and criminal justice responses to IPV. The purpose of this secondary data analysis was to determine whether use of an alternate light source (ALS) increased the predictive probability of successfully detecting bruises on diverse skin tones following a history of physical trauma. In this study, data were analyzed from a convenience sample of 157 subjects inclusive of six skin tones (very light, light, intermediate, tan, brown, dark) with induced bruises. Bruises were assessed under white light and an ALS 21 times over four weeks using 10 different ALS wavelength and goggle color combinations. Data analyzed included 31,841 skin observations obtained over 2897 participant assessments. Multilevel modeling was used to account for the correlation among the repeated measurements for each bruise. Across all categories of skin pigmentation, ALS wavelengths 415 nm and 450 nm viewed through a yellow filter had the most frequent detections of bruises (415 nm: n = 2777, 11.2%; 450 nm: n = 2747, 11.1%) and greater predictive probability of a positive finding (415 nm: 0.90-0.99; 450 nm: 0.85-0.99) than white light (n = 2487; 10%; 0.81-0.90). These two ALS wavelengths were the only combinations that provided greater probability of detection than white light on groups with darker skin (brown or dark), whereas additional ALS wavelengths/filters worked equally well on groups with lighter skin. Findings suggest use of an ALS in clinical assessments of patients of color who report IPV may help reduce health and criminal justice-related disparities.
dc.identifier.doi10.1016/j.forsciint.2022.111410
dc.identifier.issn1872-6283
dc.identifier.pubmed35940073
dc.identifier.urihttps://hdl.handle.net/20.500.12597/3300
dc.language.isoen
dc.relation.ispartofForensic science international
dc.subjectAlternate light source
dc.subjectBruise
dc.subjectDetection
dc.subjectForensic
dc.subjectSkin pigmentation
dc.titlePredicting alternate light absorption in areas of trauma based on degree of skin pigmentation: Not all wavelengths are equal.
dc.typeJournal Article
dspace.entity.typePubmed
oaire.citation.volume339
relation.isPublicationOfPubmeda75bffc0-cb34-498b-b56f-b9e130860dcf
relation.isPublicationOfPubmed.latestForDiscoverya75bffc0-cb34-498b-b56f-b9e130860dcf

Files