| dc.description.abstract | Accurate and rapid measurement of blood β-hydroxybutyrate (β-OHB) concentrations is critical to identify hyperketonemia in sheep. | |
| dc.description.abstract | The objective of this study was to test the performance of Freestyle Optium Neo H and TaiDoc-TD4235 point-of-care (POC) devices for measuring blood β-OHB concentrations in sheep. | |
| dc.description.abstract | Venous blood samples from 105 sheep were evaluated with Freestyle Optium Neo H and TaiDoc-TD4235 meters. A reference approach was the laboratory measurement of serum BHB concentrations using the Randox D-3 Hydroxybutyrate reagent kit. Data were analyzed using Passing- Bablok regression and Bland-Altman analysis. The diagnostic accuracy was assessed using serum β-OHB concentration at a cut-off value of 0.8 mmol/L. | |
| dc.description.abstract | Passing-Bablok regression analysis revealed an intercept of 0.066 (CI : 0.018-0.125) and slope of 1.242 (CI : 1.136-1.342) for Freestyle Optium Neo H. Intercept and slope values for the TaiDoc-TD4235 meter were 0.625 (CI : 0.539-0.724) and 1.265 (CI : 1.044-1.497), respectively. The Bland-Altman plot revealed a bias of 0.224 mmol/L and 0.737 mmol/L for Freestyle Optium Neo H and TaiDoc-TD4235 meters, respectively, compared with the reference method. Observed Total Error (TE ) was 56.7% for the Freestyle Optium Neo H and 168.7% for the Taidoc-TD4235. The sensitivity and specificity for the Freestyle Optium Neo H were 100% and 80.9%, respectively, at the threshold of 0.8 mmol/L. The Taidoc-TD4235 demonstrated a sensitivity of 93.3% and specificity of 8.9% at the threshold of 0.8 mmol/L. | |
| dc.description.abstract | Because of the large TE , the Freestyle Optium Neo H and TaiDoc-TD4235 meters should not be used to quantify blood β-OHB concentrations in sheep. | |
| dc.identifier.doi | 10.1111/vcp.13223 | |
| dc.identifier.issn | 1939-165X | |
| dc.identifier.pubmed | 36859602 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.12597/3233 | |
| dc.language.iso | en | |
| dc.relation.ispartof | Veterinary clinical pathology | |
| dc.subject | bias | |
| dc.subject | ewe | |
| dc.subject | point-of-care device | |
| dc.subject | pregnancy toxemia | |
| dc.subject | sensitivity | |
| dc.subject | specificity | |
| dc.title | Evaluation of Freestyle Optium Neo H and TaiDoc-TD4235 point-of-care meters for measuring blood β-hydroxybutyrate concentration in sheep. | |
| dc.type | Journal Article | |
| dspace.entity.type | Pubmed | |
| local.indexed.at | PubMed | |
| relation.isPublicationOfPubmed | 11ef2c2d-ca89-4205-a11b-9bf428ddde64 | |
| relation.isPublicationOfPubmed.latestForDiscovery | 11ef2c2d-ca89-4205-a11b-9bf428ddde64 |