Publication:
Static lateral load capacity of extruded wood-plastic composite-to-metal single-bolt connections, considering failure at the ends

dc.contributor.authorChen C., Kuang F., Tor O., Quin F., Xiong Z., Zhang J.
dc.contributor.authorChen, C, Kuang, FC, Tor, O, Quin, F, Xiong, ZW, Zhang, JL
dc.date.accessioned2023-05-09T18:53:07Z
dc.date.available2023-05-09T18:53:07Z
dc.date.issued2019-01-01
dc.date.issued2019.01.01
dc.description.abstractThe effect of the end distance was studied relative to the static ultimate lateral load capacity of a single-shear unconstrained wood-plastic-composite-to-metal single-bolt connection (SUWSC). Equations estimated the static ultimate lateral loads of the SUWSCs that failed during the end tear-out, splitting, and yield modes and were obtained using stress concentration factor regression- and mechanics-based approaches. The experimental results showed that the stress concentration factor was a linear function of the end-distance to bolt-diameter ratio for the SUWSCs that failed during end tear-out and splitting modes. The static ultimate lateral loads of the SUWSCs that failed during the yield modes were estimated using a mechanics-based equation. The minimum end distance for the SUWSCs that failed without end fracture (i.e., only with yield mode) was 25.4 mm, which was four times larger than the bolt diameter.
dc.identifier.doi10.15376/biores.14.4.8987-9000
dc.identifier.endpage9000
dc.identifier.issn1930-2126
dc.identifier.scopus2-s2.0-85075231493
dc.identifier.startpage8987
dc.identifier.urihttps://hdl.handle.net/20.500.12597/13767
dc.identifier.volume14
dc.identifier.wosWOS:000493997400099
dc.relation.ispartofBioResources
dc.relation.ispartofBIORESOURCES
dc.rightsfalse
dc.subjectEnd tear-out | Shear strength | Single-shear bolted connections | Splitting | Stress concentration factor | Tensile strength | Wood-plastic composites
dc.titleStatic lateral load capacity of extruded wood-plastic composite-to-metal single-bolt connections, considering failure at the ends
dc.titleStatic Lateral Load Capacity of Extruded Wood-plastic Composite-to-metal Single-bolt Connections, Considering Failure at the Ends
dc.typeArticle
dspace.entity.typePublication
oaire.citation.issue4
oaire.citation.volume14
relation.isScopusOfPublication45f02e67-c218-4734-84c8-e03ca0d2741b
relation.isScopusOfPublication.latestForDiscovery45f02e67-c218-4734-84c8-e03ca0d2741b
relation.isWosOfPublicationa381025c-2ef7-4180-9155-05a4e52544c5
relation.isWosOfPublication.latestForDiscoverya381025c-2ef7-4180-9155-05a4e52544c5

Files

Collections