Publication:
Ultrasonographic and macroscopic comparison of the thickness of the capsule, corium, and soft tissues in bovine claws: An in vitro study

dc.contributor.authorCecen G., Salci H., Intas D.S., Celimli N., Caliskan G.U.
dc.contributor.authorCecen, G, Salci, H, Intas, DS, Celimli, N, Caliskan, GU
dc.date.accessioned2023-05-09T20:32:52Z
dc.date.available2023-05-09T20:32:52Z
dc.date.issued2015-01-01
dc.date.issued2015.01.01
dc.description.abstractThis study aimed to compare thickness of the capsule, corium, and soft tissues measured ultrasonographically and macroscopically in selected regions of bovine claws. A hundred and twenty claws (n = 120) of 15 healthy Holstein bovines were obtained. After cleaning the claws, ultrasonographic measurement of the capsule, corium, and soft tissues was performed while submerging the claws in a water bath. Macroscopic measurements were taken after cutting of the claws axially. These values were compared statistically. According to the macroscopic measurements, the mean thickness ± standard deviation (SD) of the capsule for dorsal wall and sole was 6.2 ± 0.1 and 9.5 ± 0.4 mm, respectively. The thickness of the corium and soft tissues for dorsal wall and sole was 4.5 ± 0.1 and 5.3 ± 0.1 mm, respectively. Ultrasonographically, the mean thickness ± SD of the capsule for dorsal wall and sole was 4.7 ± 0.1 and 7.8 ± 0.3 mm, respectively. The thickness of the corium and soft tissues for dorsal wall and sole was 4.3 ± 0.1 and 5.9 ± 0.2 mm, respectively. Findings demonstrated that ultrasonography can be reliably to measure of the thickness of the hoof capsule, corium, and soft tissue in bovine claw.
dc.identifier.doi10.4142/jvs.2015.16.1.107
dc.identifier.eissn1976-555X
dc.identifier.endpage112
dc.identifier.issn1229-845X
dc.identifier.scopus2-s2.0-84928538296
dc.identifier.startpage107
dc.identifier.urihttps://hdl.handle.net/20.500.12597/15177
dc.identifier.volume16
dc.identifier.wosWOS:000351480900014
dc.relation.ispartofJournal of Veterinary Science
dc.relation.ispartofJOURNAL OF VETERINARY SCIENCE
dc.rightstrue
dc.subjectBovine claw | Ultrasound
dc.titleUltrasonographic and macroscopic comparison of the thickness of the capsule, corium, and soft tissues in bovine claws: An in vitro study
dc.titleUltrasonographic and macroscopic comparison of the thickness of the capsule, corium, and soft tissues in bovine claws: an in vitro study
dc.typeArticle
dspace.entity.typePublication
oaire.citation.issue1
oaire.citation.volume16
relation.isScopusOfPublication7220b446-0620-4a0c-9134-ccedeee0e2c3
relation.isScopusOfPublication.latestForDiscovery7220b446-0620-4a0c-9134-ccedeee0e2c3
relation.isWosOfPublication507066f5-6d08-48e1-9094-7d8a7e19c763
relation.isWosOfPublication.latestForDiscovery507066f5-6d08-48e1-9094-7d8a7e19c763

Files

Collections