dc.description.abstractMetalworking fluids (MWFs), which have a long history of use in industry and are in constant and ever-increasing use in parallel with advancements in mechanisation, are emulsions prepared with water. MWFs prepared as a 1/20 (MWF: water) mixture in practice, contain a large amount of water within their structure, and may become an aquatic toxic mixture in an ecosystem. In this study, half maximal effective concentration (EC50) values for MWFs were determined using the Allium cepa test, an accepted ecotoxicological biomonitor, and test solutions were prepared (1/250, 1/500 and 1/1000). Depending on the MWF ratio at each concentration, a decrease in the mitotic index (MI), irregularities in the phase distribution and aberrations in the chromosomes were observed. When the amount of MWF in the water increased, chromosomal abnormalities such as stickiness were observed to occur; whereas abnormalities such as c-mitosis, fragments, bridges, vagrants and micronucleus increased as the amount of the MWF decreased. Over a second 24-h period, it was observed that values, in particular MI, showed a tendency to return to normal. © 2013 © 2013 Taylor & Francis.
dc.identifier.doi10.1080/02757540.2013.831079
dc.identifier.eissn1029-0370
dc.identifier.endpage75
dc.identifier.issn0275-7540
dc.identifier.scopus2-s2.0-84895065818
dc.identifier.startpage66
dc.identifier.urihttps://hdl.handle.net/20.500.12597/13161
dc.identifier.volume30
dc.identifier.wosWOS:000337184000006
dc.relation.ispartofChemistry and Ecology
dc.relation.ispartofCHEMISTRY AND ECOLOGY
dc.rightsfalse
dc.subjectAllium cepa | bioassay | chromosomal abnormalities | genotoxicity | metalworking fluids | mitotic index
dc.titleEcotoxicological assessment of metalworking fluids using the Allium cepa test procedure
dc.titleEcotoxicological assessment of metalworking fluids using the Allium cepa test procedure
dc.typeArticle
dspace.entity.typePublication
oaire.citation.issue1
oaire.citation.volume30
relation.isScopusOfPublication4a838ed4-7fc4-439c-897e-389454f5b9e6
relation.isScopusOfPublication.latestForDiscovery4a838ed4-7fc4-439c-897e-389454f5b9e6
relation.isWosOfPublicationc3007ab0-2563-4046-99e5-6ae5a8d43437
relation.isWosOfPublication.latestForDiscoveryc3007ab0-2563-4046-99e5-6ae5a8d43437

Files

Collections