Yayın:
Comparison of Average Current Controlled PFC SEPIC and CUK Converter Feeding Current Controlled SRM

dc.contributor.authorŞehirli, Erdal
dc.contributor.authorÇetinceviz, Yücel
dc.date.accessioned2026-01-04T17:33:53Z
dc.date.issued2022-12-15
dc.description.abstractIn this paper, current control of 6/4 switched reluctance motor (SRM) fed by both power factor correction (PFC) SEPIC and CUK converter is realised and asymmetric bridge converter is used to drive SRM. Furthermore, SEPIC and CUK DC-DC converters are connected in series to diode bridge rectifier in order to build PFC converters. Average current control of PFC converters is carried out by PI algorithm and both converters are operated at continuous conduction mode (CCM). Besides, switching frequency of PFC and asymmetric bridge converters is 62, 9 kHz with 5750 W power. Studies are conducted by using MATLAB/Simulink software. Total harmonic distortions (THD)s of grid current, grid power factor (PF) and output voltages of the converters are compared. Also, THDs of grid current of each converter are compared by IEEE 519-2014 standard. In addition, current waveform and flux of SRM phases are shown. It is validated by simulations that PFC CUK converter gives better result with 9.08% THD, 0.998 PF than PFC SEPIC converter having 9.61% THD and 0.997 PF. Furthermore, both converters provide the limit defined by standards.
dc.description.urihttps://doi.org/10.17559/tv-20181108110207
dc.description.urihttps://doaj.org/article/655e11727c82468fb952a96e5bb3d372
dc.description.urihttps://doi.org/10.17559/TV-20181108110207
dc.description.urihttps://hrcak.srce.hr/284890
dc.description.urihttps://hrcak.srce.hr/file/412440
dc.identifier.doi10.17559/tv-20181108110207
dc.identifier.eissn1848-6339
dc.identifier.issn1330-3651
dc.identifier.openairedoi_dedup___::af684cf74933632fc6092c0dcd4ac776
dc.identifier.orcid0000-0003-0822-3201
dc.identifier.orcid0000-0001-6834-9442
dc.identifier.scopus2-s2.0-85140822811
dc.identifier.urihttps://hdl.handle.net/20.500.12597/40207
dc.identifier.volume29
dc.identifier.wos000897778600001
dc.publisherMechanical Engineering Faculty in Slavonski Brod
dc.relation.ispartofTehnicki vjesnik - Technical Gazette
dc.rightsOPEN
dc.subjectPFC
dc.subjectSRM
dc.subjectTHD
dc.subjectCUK
dc.subjectTA1-2040
dc.subjectEngineering (General). Civil engineering (General)
dc.subjectSEPIC
dc.subject.sdg7. Clean energy
dc.titleComparison of Average Current Controlled PFC SEPIC and CUK Converter Feeding Current Controlled SRM
dc.typeArticle
dspace.entity.typePublication
local.api.response{"authors":[{"fullName":"Şehirli, Erdal","name":"Erdal","surname":"Şehirli","rank":1,"pid":{"id":{"scheme":"orcid_pending","value":"0000-0003-0822-3201"},"provenance":null}},{"fullName":"Çetinceviz, Yücel","name":"Yücel","surname":"Çetinceviz","rank":2,"pid":{"id":{"scheme":"orcid","value":"0000-0001-6834-9442"},"provenance":null}}],"openAccessColor":"gold","publiclyFunded":false,"type":"publication","language":{"code":"und","label":"Undetermined"},"countries":null,"subjects":[{"subject":{"scheme":"keyword","value":"PFC"},"provenance":null},{"subject":{"scheme":"keyword","value":"SRM"},"provenance":null},{"subject":{"scheme":"FOS","value":"0209 industrial biotechnology"},"provenance":null},{"subject":{"scheme":"keyword","value":"THD"},"provenance":null},{"subject":{"scheme":"keyword","value":"CUK"},"provenance":null},{"subject":{"scheme":"FOS","value":"0202 electrical engineering, electronic engineering, information engineering"},"provenance":null},{"subject":{"scheme":"FOS","value":"02 engineering and technology"},"provenance":null},{"subject":{"scheme":"keyword","value":"TA1-2040"},"provenance":null},{"subject":{"scheme":"keyword","value":"Engineering (General). Civil engineering (General)"},"provenance":null},{"subject":{"scheme":"SDG","value":"7. Clean energy"},"provenance":null},{"subject":{"scheme":"keyword","value":"SEPIC"},"provenance":null}],"mainTitle":"Comparison of Average Current Controlled PFC SEPIC and CUK Converter Feeding Current Controlled SRM","subTitle":null,"descriptions":["In this paper, current control of 6/4 switched reluctance motor (SRM) fed by both power factor correction (PFC) SEPIC and CUK converter is realised and asymmetric bridge converter is used to drive SRM. Furthermore, SEPIC and CUK DC-DC converters are connected in series to diode bridge rectifier in order to build PFC converters. Average current control of PFC converters is carried out by PI algorithm and both converters are operated at continuous conduction mode (CCM). Besides, switching frequency of PFC and asymmetric bridge converters is 62, 9 kHz with 5750 W power. Studies are conducted by using MATLAB/Simulink software. Total harmonic distortions (THD)s of grid current, grid power factor (PF) and output voltages of the converters are compared. Also, THDs of grid current of each converter are compared by IEEE 519-2014 standard. In addition, current waveform and flux of SRM phases are shown. It is validated by simulations that PFC CUK converter gives better result with 9.08% THD, 0.998 PF than PFC SEPIC converter having 9.61% THD and 0.997 PF. Furthermore, both converters provide the limit defined by standards."],"publicationDate":"2022-12-15","publisher":"Mechanical Engineering Faculty in Slavonski Brod","embargoEndDate":null,"sources":["Crossref","Tehnički Vjesnik, Vol 29, Iss 6, Pp 1789-1795 (2022)","Tehnički vjesnik","ISSN 1848-6339 (Online)","ISSN 1330-3651 (Print)","ISSN-L 1330-3651","Volume 29","Issue 6"],"formats":["application/pdf"],"contributors":null,"coverages":null,"bestAccessRight":{"code":"c_abf2","label":"OPEN","scheme":"http://vocabularies.coar-repositories.org/documentation/access_rights/"},"container":{"name":"Tehnicki vjesnik - Technical Gazette","issnPrinted":"1330-3651","issnOnline":"1848-6339","issnLinking":null,"ep":null,"iss":null,"sp":null,"vol":"29","edition":null,"conferencePlace":null,"conferenceDate":null},"documentationUrls":null,"codeRepositoryUrl":null,"programmingLanguage":null,"contactPeople":null,"contactGroups":null,"tools":null,"size":null,"version":null,"geoLocations":null,"id":"doi_dedup___::af684cf74933632fc6092c0dcd4ac776","originalIds":["10.17559/tv-20181108110207","50|doiboost____|af684cf74933632fc6092c0dcd4ac776","50|doajarticles::4b2ccc676fb4a9ca41da11997eb690f1","oai:doaj.org/article:655e11727c82468fb952a96e5bb3d372","oai:hrcak.srce.hr:284890","50|od_______951::249c50a502e5e36c361b3766e7100772"],"pids":[{"scheme":"doi","value":"10.17559/tv-20181108110207"}],"dateOfCollection":null,"lastUpdateTimeStamp":null,"indicators":{"citationImpact":{"citationCount":0,"influence":2.5349236e-9,"popularity":1.8548826e-9,"impulse":0,"citationClass":"C5","influenceClass":"C5","impulseClass":"C5","popularityClass":"C5"}},"instances":[{"pids":[{"scheme":"doi","value":"10.17559/tv-20181108110207"}],"type":"Article","urls":["https://doi.org/10.17559/tv-20181108110207"],"publicationDate":"2022-12-15","refereed":"peerReviewed"},{"alternateIdentifiers":[{"scheme":"doi","value":"10.17559/tv-20181108110207"}],"type":"Article","urls":["https://doaj.org/article/655e11727c82468fb952a96e5bb3d372"],"publicationDate":"2022-01-01","refereed":"nonPeerReviewed"},{"alternateIdentifiers":[{"scheme":"doi","value":"10.17559/tv-20181108110207"}],"type":"Article","urls":["https://doi.org/10.17559/TV-20181108110207","https://hrcak.srce.hr/284890","https://hrcak.srce.hr/file/412440"],"publicationDate":"2022-01-01","refereed":"nonPeerReviewed"},{"alternateIdentifiers":[{"scheme":"doi","value":"10.17559/tv-20181108110207"}],"type":"Article","urls":["https://hrcak.srce.hr/284890","https://doi.org/10.17559/tv-20181108110207"],"publicationDate":"2022-10-29","refereed":"nonPeerReviewed"}],"isGreen":false,"isInDiamondJournal":false}