Yayın:
Soft switching maximum power point tracker with resonant switch in PV system

dc.contributor.authorOncu, Selim
dc.contributor.authorNacar, Salih
dc.date.accessioned2026-01-02T23:44:28Z
dc.date.issued2016-08-01
dc.description.abstractAbstract Conventional boost converters are used in many applications such as power factor correction, electronic ballasts, battery chargers, photovoltaic (PV) applications. PV systems need maximum power point tracker (MPPT) to have efficient power conversion. Maximum power point trackers are usually implemented by pulse width modulation (PWM) controlled converters. In PWM control, the switching losses and the voltage–current stresses of the device increase. In the present paper, an MPPT with soft switching boost converter is designed, simulated and experimentally tested. The topology adds a resonant network to the conventional boost converter and controls the PV power by changing the switching frequency. In the proposed converter, Perturb & Observe method is used as power tracking algorithm that is implemented with dsPIC30F2020 and zero voltage switching (ZVS) is achieved in wide range. The variable frequency controlled MPPT is tested for different radiation levels and loads and switching characteristic is compared with PWM controlled boost converter. The proposed single switch resonant converter is simulated in PSIM and experimental validation is also given for a 40 W PV generation system.
dc.description.urihttps://doi.org/10.1016/j.ijhydene.2016.01.088
dc.description.urihttps://dx.doi.org/10.1016/j.ijhydene.2016.01.088
dc.identifier.doi10.1016/j.ijhydene.2016.01.088
dc.identifier.endpage12484
dc.identifier.issn0360-3199
dc.identifier.openairedoi_dedup___::c41604db53522efea4cacc6bd9c9e1a4
dc.identifier.orcid0000-0003-4843-9648
dc.identifier.scopus2-s2.0-84957927325
dc.identifier.startpage12477
dc.identifier.urihttps://hdl.handle.net/20.500.12597/36230
dc.identifier.volume41
dc.identifier.wos000380869700005
dc.language.isoeng
dc.publisherElsevier BV
dc.relation.ispartofInternational Journal of Hydrogen Energy
dc.rightsCLOSED
dc.subject.sdg7. Clean energy
dc.titleSoft switching maximum power point tracker with resonant switch in PV system
dc.typeArticle
dspace.entity.typePublication
local.api.response{"authors":[{"fullName":"Selim Oncu","name":"Selim","surname":"Oncu","rank":1,"pid":null},{"fullName":"Salih Nacar","name":"Salih","surname":"Nacar","rank":2,"pid":{"id":{"scheme":"orcid","value":"0000-0003-4843-9648"},"provenance":null}}],"openAccessColor":null,"publiclyFunded":false,"type":"publication","language":{"code":"eng","label":"English"},"countries":null,"subjects":[{"subject":{"scheme":"FOS","value":"0202 electrical engineering, electronic engineering, information engineering"},"provenance":null},{"subject":{"scheme":"FOS","value":"02 engineering and technology"},"provenance":null},{"subject":{"scheme":"FOS","value":"0204 chemical engineering"},"provenance":null},{"subject":{"scheme":"SDG","value":"7. Clean energy"},"provenance":null}],"mainTitle":"Soft switching maximum power point tracker with resonant switch in PV system","subTitle":null,"descriptions":["Abstract Conventional boost converters are used in many applications such as power factor correction, electronic ballasts, battery chargers, photovoltaic (PV) applications. PV systems need maximum power point tracker (MPPT) to have efficient power conversion. Maximum power point trackers are usually implemented by pulse width modulation (PWM) controlled converters. In PWM control, the switching losses and the voltage–current stresses of the device increase. In the present paper, an MPPT with soft switching boost converter is designed, simulated and experimentally tested. The topology adds a resonant network to the conventional boost converter and controls the PV power by changing the switching frequency. In the proposed converter, Perturb & Observe method is used as power tracking algorithm that is implemented with dsPIC30F2020 and zero voltage switching (ZVS) is achieved in wide range. The variable frequency controlled MPPT is tested for different radiation levels and loads and switching characteristic is compared with PWM controlled boost converter. The proposed single switch resonant converter is simulated in PSIM and experimental validation is also given for a 40 W PV generation system."],"publicationDate":"2016-08-01","publisher":"Elsevier BV","embargoEndDate":null,"sources":["Crossref"],"formats":null,"contributors":null,"coverages":null,"bestAccessRight":{"code":"c_14cb","label":"CLOSED","scheme":"http://vocabularies.coar-repositories.org/documentation/access_rights/"},"container":{"name":"International Journal of Hydrogen Energy","issnPrinted":"0360-3199","issnOnline":null,"issnLinking":null,"ep":"12484","iss":null,"sp":"12477","vol":"41","edition":null,"conferencePlace":null,"conferenceDate":null},"documentationUrls":null,"codeRepositoryUrl":null,"programmingLanguage":null,"contactPeople":null,"contactGroups":null,"tools":null,"size":null,"version":null,"geoLocations":null,"id":"doi_dedup___::c41604db53522efea4cacc6bd9c9e1a4","originalIds":["S0360319915314361","10.1016/j.ijhydene.2016.01.088","50|doiboost____|c41604db53522efea4cacc6bd9c9e1a4","2267756368"],"pids":[{"scheme":"doi","value":"10.1016/j.ijhydene.2016.01.088"}],"dateOfCollection":null,"lastUpdateTimeStamp":null,"indicators":{"citationImpact":{"citationCount":11,"influence":3.840887e-9,"popularity":4.232072e-9,"impulse":8,"citationClass":"C5","influenceClass":"C4","impulseClass":"C4","popularityClass":"C4"}},"instances":[{"pids":[{"scheme":"doi","value":"10.1016/j.ijhydene.2016.01.088"}],"license":"Elsevier TDM","type":"Article","urls":["https://doi.org/10.1016/j.ijhydene.2016.01.088"],"publicationDate":"2016-08-01","refereed":"peerReviewed"},{"alternateIdentifiers":[{"scheme":"doi","value":"10.1016/j.ijhydene.2016.01.088"},{"scheme":"mag_id","value":"2267756368"}],"type":"Article","urls":["https://dx.doi.org/10.1016/j.ijhydene.2016.01.088"],"refereed":"nonPeerReviewed"}],"isGreen":false,"isInDiamondJournal":false}