Yayın:
Speed Control of PMSM Fed By Bridgeless PFC Isolated Cuk Converter Using LCL filter

dc.contributor.authorHukumen, Burhan
dc.contributor.authorSehirli, Erdal
dc.date.accessioned2026-01-05T23:12:48Z
dc.date.issued2021-07-06
dc.description.abstractIn this paper, a LCL filtered power factor corrected (PFC) converter to feed permanent magnet synchronous machines (PMSM) having field-oriented control (FOC) method has been proposed. In order to compensate the total harmonic distortion (THD) and poor power factor (PF) problem while achieving the high efficiency and reducing the switching losses of the converter and the voltage source inverter (VSI), the proposed system has been designed as LCL filtered bridgeless single-stage PFC isolated cuk converter for low power applications. Value of the output inductor provides discontinuous conduction mode (DCM) operation for reducing the conduction losses on switches of the converter. On the other hand, source filter was designed as LCL type to ensure power quality improvement. Results of this paper through the simulation have demonstrated that the proposed system has a capability to drive low power applications within the boundaries of international power quality standards and speed of the PMSM was controlled as desired.
dc.description.urihttps://doi.org/10.1109/eurocon52738.2021.9535536
dc.description.urihttps://dx.doi.org/10.1109/eurocon52738.2021.9535536
dc.identifier.doi10.1109/eurocon52738.2021.9535536
dc.identifier.endpage437
dc.identifier.openairedoi_dedup___::8c382f34ab42ca936493ed70087ffaeb
dc.identifier.orcid0000-0003-0822-3201
dc.identifier.scopus2-s2.0-85116266551
dc.identifier.startpage432
dc.identifier.urihttps://hdl.handle.net/20.500.12597/43643
dc.identifier.wos000728121700080
dc.publisherIEEE
dc.relation.ispartofIEEE EUROCON 2021 - 19th International Conference on Smart Technologies
dc.rightsCLOSED
dc.subject.sdg7. Clean energy
dc.titleSpeed Control of PMSM Fed By Bridgeless PFC Isolated Cuk Converter Using LCL filter
dc.typeArticle
dspace.entity.typePublication
local.api.response{"authors":[{"fullName":"Burhan Hukumen","name":"Burhan","surname":"Hukumen","rank":1,"pid":null},{"fullName":"Erdal Sehirli","name":"Erdal","surname":"Sehirli","rank":2,"pid":{"id":{"scheme":"orcid","value":"0000-0003-0822-3201"},"provenance":null}}],"openAccessColor":null,"publiclyFunded":false,"type":"publication","language":{"code":"und","label":"Undetermined"},"countries":null,"subjects":[{"subject":{"scheme":"SDG","value":"7. Clean energy"},"provenance":null}],"mainTitle":"Speed Control of PMSM Fed By Bridgeless PFC Isolated Cuk Converter Using LCL filter","subTitle":null,"descriptions":["In this paper, a LCL filtered power factor corrected (PFC) converter to feed permanent magnet synchronous machines (PMSM) having field-oriented control (FOC) method has been proposed. In order to compensate the total harmonic distortion (THD) and poor power factor (PF) problem while achieving the high efficiency and reducing the switching losses of the converter and the voltage source inverter (VSI), the proposed system has been designed as LCL filtered bridgeless single-stage PFC isolated cuk converter for low power applications. Value of the output inductor provides discontinuous conduction mode (DCM) operation for reducing the conduction losses on switches of the converter. On the other hand, source filter was designed as LCL type to ensure power quality improvement. Results of this paper through the simulation have demonstrated that the proposed system has a capability to drive low power applications within the boundaries of international power quality standards and speed of the PMSM was controlled as desired."],"publicationDate":"2021-07-06","publisher":"IEEE","embargoEndDate":null,"sources":["Crossref"],"formats":null,"contributors":null,"coverages":null,"bestAccessRight":{"code":"c_14cb","label":"CLOSED","scheme":"http://vocabularies.coar-repositories.org/documentation/access_rights/"},"container":{"name":"IEEE EUROCON 2021 - 19th International Conference on Smart Technologies","issnPrinted":null,"issnOnline":null,"issnLinking":null,"ep":"437","iss":null,"sp":"432","vol":null,"edition":null,"conferencePlace":null,"conferenceDate":null},"documentationUrls":null,"codeRepositoryUrl":null,"programmingLanguage":null,"contactPeople":null,"contactGroups":null,"tools":null,"size":null,"version":null,"geoLocations":null,"id":"doi_dedup___::8c382f34ab42ca936493ed70087ffaeb","originalIds":["10.1109/eurocon52738.2021.9535536","50|doiboost____|8c382f34ab42ca936493ed70087ffaeb","3201028969"],"pids":[{"scheme":"doi","value":"10.1109/eurocon52738.2021.9535536"}],"dateOfCollection":null,"lastUpdateTimeStamp":null,"indicators":{"citationImpact":{"citationCount":1,"influence":2.6405453e-9,"popularity":2.3979547e-9,"impulse":1,"citationClass":"C5","influenceClass":"C5","impulseClass":"C5","popularityClass":"C5"}},"instances":[{"pids":[{"scheme":"doi","value":"10.1109/eurocon52738.2021.9535536"}],"license":"IEEE Copyright","type":"Article","urls":["https://doi.org/10.1109/eurocon52738.2021.9535536"],"publicationDate":"2021-07-06","refereed":"peerReviewed"},{"alternateIdentifiers":[{"scheme":"mag_id","value":"3201028969"},{"scheme":"doi","value":"10.1109/eurocon52738.2021.9535536"}],"type":"Article","urls":["https://dx.doi.org/10.1109/eurocon52738.2021.9535536"],"refereed":"nonPeerReviewed"}],"isGreen":false,"isInDiamondJournal":false}
local.import.sourceOpenAire
local.indexed.atWOS
local.indexed.atScopus

Dosyalar

Koleksiyonlar