dc.description.abstractIn this study, it was aimed to produce a low cost customized orthopedic insole and perform its pressure analyzes. In this analysis, it was used thin film pressure sensor and Arduino programming platform equipped with ATmega328 microcontroller. For the sensor layout, 5 zones were determined in the sole and the proportional values with the pressure were recorded and these values were used for the insole design. For the pressure analysis, 17 volunteers aged 19 to 34 years, with flatfoot and normal foot participated for the experiments. A center line was determined to provide a balanced distribution of the pressure in the sole and a mathematical model was created for this distribution. Through this model, the data obtained from the experiments was normalized and the appropriate height values were calculated for the insole zones. In addition to this study, the reduction degree of pressure applied to the sole of a 9 mm high foam material placed on the heel of the foot was measured.
dc.description.urihttps://doi.org/10.1109/tiptekno.2018.8596881
dc.description.urihttps://dx.doi.org/10.1109/tiptekno.2018.8596881
dc.identifier.doi10.1109/tiptekno.2018.8596881
dc.identifier.endpage4
dc.identifier.openairedoi_dedup___::5a792cda9a9092f5bb097fd60e61f052
dc.identifier.scopus2-s2.0-85061757695
dc.identifier.startpage1
dc.identifier.urihttps://hdl.handle.net/20.500.12597/37015
dc.publisherIEEE
dc.relation.ispartof2018 Medical Technologies National Congress (TIPTEKNO)
dc.rightsCLOSED
dc.titleOrthopedic Insole Design and Pressure Analyzes
dc.typeArticle
dspace.entity.typePublication
local.api.response{"authors":[{"fullName":"Salih Özkan","name":"Salih","surname":"Özkan","rank":1,"pid":null},{"fullName":"Hayriye Altural","name":"Hayriye","surname":"Altural","rank":2,"pid":null},{"fullName":"Güzin Çakır Kandemirli","name":"Güzin Çakır","surname":"Kandemirli","rank":3,"pid":null},{"fullName":"Fatma Kandemirli","name":"Fatma","surname":"Kandemirli","rank":4,"pid":null}],"openAccessColor":null,"publiclyFunded":false,"type":"publication","language":{"code":"und","label":"Undetermined"},"countries":null,"subjects":[{"subject":{"scheme":"FOS","value":"0103 physical sciences"},"provenance":null},{"subject":{"scheme":"FOS","value":"0202 electrical engineering, electronic engineering, information engineering"},"provenance":null},{"subject":{"scheme":"FOS","value":"02 engineering and technology"},"provenance":null},{"subject":{"scheme":"FOS","value":"01 natural sciences"},"provenance":null}],"mainTitle":"Orthopedic Insole Design and Pressure Analyzes","subTitle":null,"descriptions":["In this study, it was aimed to produce a low cost customized orthopedic insole and perform its pressure analyzes. In this analysis, it was used thin film pressure sensor and Arduino programming platform equipped with ATmega328 microcontroller. For the sensor layout, 5 zones were determined in the sole and the proportional values with the pressure were recorded and these values were used for the insole design. For the pressure analysis, 17 volunteers aged 19 to 34 years, with flatfoot and normal foot participated for the experiments. A center line was determined to provide a balanced distribution of the pressure in the sole and a mathematical model was created for this distribution. Through this model, the data obtained from the experiments was normalized and the appropriate height values were calculated for the insole zones. In addition to this study, the reduction degree of pressure applied to the sole of a 9 mm high foam material placed on the heel of the foot was measured."],"publicationDate":"2018-11-01","publisher":"IEEE","embargoEndDate":null,"sources":["Crossref"],"formats":null,"contributors":null,"coverages":null,"bestAccessRight":{"code":"c_14cb","label":"CLOSED","scheme":"http://vocabularies.coar-repositories.org/documentation/access_rights/"},"container":{"name":"2018 Medical Technologies National Congress (TIPTEKNO)","issnPrinted":null,"issnOnline":null,"issnLinking":null,"ep":"4","iss":null,"sp":"1","vol":null,"edition":null,"conferencePlace":null,"conferenceDate":null},"documentationUrls":null,"codeRepositoryUrl":null,"programmingLanguage":null,"contactPeople":null,"contactGroups":null,"tools":null,"size":null,"version":null,"geoLocations":null,"id":"doi_dedup___::5a792cda9a9092f5bb097fd60e61f052","originalIds":["10.1109/tiptekno.2018.8596881","50|doiboost____|5a792cda9a9092f5bb097fd60e61f052","2910448284"],"pids":[{"scheme":"doi","value":"10.1109/tiptekno.2018.8596881"}],"dateOfCollection":null,"lastUpdateTimeStamp":null,"indicators":{"citationImpact":{"citationCount":0,"influence":2.5349236e-9,"popularity":1.0783119e-9,"impulse":0,"citationClass":"C5","influenceClass":"C5","impulseClass":"C5","popularityClass":"C5"}},"instances":[{"pids":[{"scheme":"doi","value":"10.1109/tiptekno.2018.8596881"}],"license":"STM Policy #29","type":"Article","urls":["https://doi.org/10.1109/tiptekno.2018.8596881"],"publicationDate":"2018-11-01","refereed":"peerReviewed"},{"alternateIdentifiers":[{"scheme":"doi","value":"10.1109/tiptekno.2018.8596881"},{"scheme":"mag_id","value":"2910448284"}],"type":"Other literature type","urls":["https://dx.doi.org/10.1109/tiptekno.2018.8596881"],"refereed":"nonPeerReviewed"}],"isGreen":false,"isInDiamondJournal":false}
local.import.sourceOpenAire
local.indexed.atScopus

Dosyalar

Koleksiyonlar