Yayın:
Fabrication and characterization of model wireless biosensor-based electrochemical impedance spectroscopy (EIS) for detecting HER2 in plasma as therapeutics

dc.contributor.authorMonajjemi, Majid
dc.contributor.authorMollaamin, Fatemeh
dc.date.accessioned2026-01-04T20:39:49Z
dc.date.issued2024-07-05
dc.description.abstractPurpose Early prediction of any type of cancer is important for the treatment of this type of disease, therefore, our target to evaluate whether monitoring early changes in plasma human epidermal growth factor receptor 2 (HER2) levels (using EIS), could help in the treatment of breast cancer or not? Human epidermal growth factor receptor 2 (HER2) overexpression is an important biomarker for treatment selection in earlier stages of cancers. The combined detection of the HER2 gene in plasma for blood cancer provides an important reference index for the prognosis of metastasis to other tissues. For this purpose, the authors fabricated and characterized a model wireless biosensor-based electrochemical impedance spectroscopy (EIS) for detecting HER2 plasma as therapeutics. Design/methodology/approach Most sensors generally are fabricated based on a connection between component of the sensors and the external circuits through wires. Although these types of sensors provide suitable sensitivities and also quick responses, the connection wires can be limited to the sensing ability in various devices approximately. Therefore, the authors designed a wireless sensor, which can provide the advantages of in vivo sensing and also long-distance sensing, quickly. Findings The biosensor structure was designed for detection of HER2, HER3 and HER-4 from lab-on-chip approach with six units of screen-printed electrode (SPE), which is built of an electrochemical device of gold/silver, silver/silver or carbon electrodes. The results exhibited that the biosensor is completely selective at low concentrations of the plasma and HER2 detection via the standard addition approach has a linearity plot, therefore, by using this type of biosensors HER2 in plasma can be detected. Originality/value This is then followed by detecting HER2 in real plasma using standard way which proved to have great linearity (R2 = 0.991) proving that this technique can be used to detect HER2 solution in real patients.
dc.description.urihttps://doi.org/10.1108/sr-05-2024-0425
dc.identifier.doi10.1108/sr-05-2024-0425
dc.identifier.eissn0260-2288
dc.identifier.endpage586
dc.identifier.issn0260-2288
dc.identifier.openairedoi_________::8b84007ae8723c04707c7a74d3316292
dc.identifier.scopus2-s2.0-85197415995
dc.identifier.startpage575
dc.identifier.urihttps://hdl.handle.net/20.500.12597/41951
dc.identifier.volume44
dc.identifier.wos001261052200001
dc.language.isoeng
dc.publisherEmerald
dc.relation.ispartofSensor Review
dc.rightsCLOSED
dc.subject.sdg3. Good health
dc.titleFabrication and characterization of model wireless biosensor-based electrochemical impedance spectroscopy (EIS) for detecting HER2 in plasma as therapeutics
dc.typeArticle
dspace.entity.typePublication
local.api.response{"authors":[{"fullName":"Majid Monajjemi","name":"Majid","surname":"Monajjemi","rank":1,"pid":null},{"fullName":"Fatemeh Mollaamin","name":"Fatemeh","surname":"Mollaamin","rank":2,"pid":null}],"openAccessColor":null,"publiclyFunded":false,"type":"publication","language":{"code":"eng","label":"English"},"countries":null,"subjects":[{"subject":{"scheme":"FOS","value":"02 engineering and technology"},"provenance":null},{"subject":{"scheme":"FOS","value":"0210 nano-technology"},"provenance":null},{"subject":{"scheme":"FOS","value":"01 natural sciences"},"provenance":null},{"subject":{"scheme":"FOS","value":"0104 chemical sciences"},"provenance":null},{"subject":{"scheme":"SDG","value":"3. Good health"},"provenance":null}],"mainTitle":"Fabrication and characterization of model wireless biosensor-based electrochemical impedance spectroscopy (EIS) for detecting HER2 in plasma as therapeutics","subTitle":null,"descriptions":["<jats:sec> <jats:title content-type=\"abstract-subheading\">Purpose</jats:title> <jats:p>Early prediction of any type of cancer is important for the treatment of this type of disease, therefore, our target to evaluate whether monitoring early changes in plasma human epidermal growth factor receptor 2 (HER2) levels (using EIS), could help in the treatment of breast cancer or not? Human epidermal growth factor receptor 2 (HER2) overexpression is an important biomarker for treatment selection in earlier stages of cancers. The combined detection of the HER2 gene in plasma for blood cancer provides an important reference index for the prognosis of metastasis to other tissues. For this purpose, the authors fabricated and characterized a model wireless biosensor-based electrochemical impedance spectroscopy (EIS) for detecting HER2 plasma as therapeutics.</jats:p> </jats:sec> <jats:sec> <jats:title content-type=\"abstract-subheading\">Design/methodology/approach</jats:title> <jats:p>Most sensors generally are fabricated based on a connection between component of the sensors and the external circuits through wires. Although these types of sensors provide suitable sensitivities and also quick responses, the connection wires can be limited to the sensing ability in various devices approximately. Therefore, the authors designed a wireless sensor, which can provide the advantages of <jats:italic>in vivo</jats:italic> sensing and also long-distance sensing, quickly.</jats:p> </jats:sec> <jats:sec> <jats:title content-type=\"abstract-subheading\">Findings</jats:title> <jats:p>The biosensor structure was designed for detection of HER2, HER3 and HER-4 from lab-on-chip approach with six units of screen-printed electrode (SPE), which is built of an electrochemical device of gold/silver, silver/silver or carbon electrodes. The results exhibited that the biosensor is completely selective at low concentrations of the plasma and HER2 detection via the standard addition approach has a linearity plot, therefore, by using this type of biosensors HER2 in plasma can be detected.</jats:p> </jats:sec> <jats:sec> <jats:title content-type=\"abstract-subheading\">Originality/value</jats:title> <jats:p>This is then followed by detecting HER2 in real plasma using standard way which proved to have great linearity (<jats:italic>R</jats:italic><jats:sup>2</jats:sup> = 0.991) proving that this technique can be used to detect HER2 solution in real patients.</jats:p> </jats:sec>"],"publicationDate":"2024-07-05","publisher":"Emerald","embargoEndDate":null,"sources":["Crossref"],"formats":null,"contributors":null,"coverages":null,"bestAccessRight":{"code":"c_14cb","label":"CLOSED","scheme":"http://vocabularies.coar-repositories.org/documentation/access_rights/"},"container":{"name":"Sensor Review","issnPrinted":"0260-2288","issnOnline":"0260-2288","issnLinking":null,"ep":"586","iss":null,"sp":"575","vol":"44","edition":null,"conferencePlace":null,"conferenceDate":null},"documentationUrls":null,"codeRepositoryUrl":null,"programmingLanguage":null,"contactPeople":null,"contactGroups":null,"tools":null,"size":null,"version":null,"geoLocations":null,"id":"doi_________::8b84007ae8723c04707c7a74d3316292","originalIds":["10.1108/SR-05-2024-0425","10.1108/sr-05-2024-0425","50|doiboost____|8b84007ae8723c04707c7a74d3316292"],"pids":[{"scheme":"doi","value":"10.1108/sr-05-2024-0425"}],"dateOfCollection":null,"lastUpdateTimeStamp":null,"indicators":{"citationImpact":{"citationCount":1,"influence":2.552978e-9,"popularity":3.240752e-9,"impulse":1,"citationClass":"C5","influenceClass":"C5","impulseClass":"C5","popularityClass":"C5"}},"instances":[{"pids":[{"scheme":"doi","value":"10.1108/sr-05-2024-0425"}],"license":"Emerald Insight Site Policies","type":"Article","urls":["https://doi.org/10.1108/sr-05-2024-0425"],"publicationDate":"2024-07-05","refereed":"peerReviewed"}],"isGreen":false,"isInDiamondJournal":false}
local.import.sourceOpenAire
local.indexed.atWOS
local.indexed.atScopus

Dosyalar

Koleksiyonlar