dc.description.abstractIn order to reduce the risks of death rates, neglecting by the observers, and sometimes the little number of the medical staff in hospital, A monitoring system based microcontroller in neonatal incubator was developed in this article. An interfacing process is made between the infant, infant incubator, and the computer, by taking the temperature readings and send the results to doctor's or the person who in- charge's phone through Short Messages Service, and to a personal computer PC, with sound alarm on the incubator, every given period of time; A temperature sensor is interfaced with a configured single inline module SIM of phone, the temperature reading that obtained from interfacing method is combined with the readings of the incubator sensor, then the final result will be taken from the microcontroller because it will be more accurate than the incubator’s thermometer.
 This system was designed only to check and give an alarm if there was any unaccepted change in temperature due to the normal temperature ranges.
dc.description.urihttps://doi.org/10.9734/jerr/2019/v4i116895
dc.description.urihttps://dx.doi.org/10.9734/jerr/2019/v4i116895
dc.identifier.doi10.9734/jerr/2019/v4i116895
dc.identifier.eissn2582-2926
dc.identifier.endpage9
dc.identifier.openairedoi_dedup___::e90cf1a8f0350b75ad97b48605eda9b8
dc.identifier.orcid0000-0001-9691-8120
dc.identifier.startpage1
dc.identifier.urihttps://hdl.handle.net/20.500.12597/37260
dc.publisherSciencedomain International
dc.relation.ispartofJournal of Engineering Research and Reports
dc.rightsOPEN
dc.subject.sdg3. Good health
dc.titleNeonatal Incubator Embedded Temperature Observation and Monitoring Using GSM
dc.typeArticle
dspace.entity.typePublication
local.api.response{"authors":[{"fullName":"Fatma Kandemirli","name":"Fatma","surname":"Kandemirli","rank":1,"pid":null},{"fullName":"Yahya Zakariya Yahya","name":"Yahya Zakariya","surname":"Yahya","rank":2,"pid":{"id":{"scheme":"orcid","value":"0000-0001-9691-8120"},"provenance":null}},{"fullName":"Zaid H. Al-Sawaff","name":"Zaid H.","surname":"Al-Sawaff","rank":3,"pid":null}],"openAccessColor":"gold","publiclyFunded":false,"type":"publication","language":{"code":"und","label":"Undetermined"},"countries":null,"subjects":[{"subject":{"scheme":"FOS","value":"0203 mechanical engineering"},"provenance":null},{"subject":{"scheme":"FOS","value":"0202 electrical engineering, electronic engineering, information engineering"},"provenance":null},{"subject":{"scheme":"FOS","value":"02 engineering and technology"},"provenance":null},{"subject":{"scheme":"SDG","value":"3. Good health"},"provenance":null}],"mainTitle":"Neonatal Incubator Embedded Temperature Observation and Monitoring Using GSM","subTitle":null,"descriptions":["<jats:p>In order to reduce the risks of death rates, neglecting by the observers, and sometimes the little number of the medical staff in hospital, A monitoring system based microcontroller in neonatal incubator was developed in this article. An interfacing process is made between the infant, infant incubator, and the computer, by taking the temperature readings and send the results to doctor's or the person who in- charge's phone through Short Messages Service, and to a personal computer PC, with sound alarm on the incubator, every given period of time; A temperature sensor is interfaced with a configured single inline module SIM of phone, the temperature reading that obtained from interfacing method is combined with the readings of the incubator sensor, then the final result will be taken from the microcontroller because it will be more accurate than the incubator’s thermometer.&#x0D; This system was designed only to check and give an alarm if there was any unaccepted change in temperature due to the normal temperature ranges.</jats:p>"],"publicationDate":"2019-03-12","publisher":"Sciencedomain International","embargoEndDate":null,"sources":["Crossref"],"formats":null,"contributors":null,"coverages":null,"bestAccessRight":{"code":"c_abf2","label":"OPEN","scheme":"http://vocabularies.coar-repositories.org/documentation/access_rights/"},"container":{"name":"Journal of Engineering Research and Reports","issnPrinted":null,"issnOnline":"2582-2926","issnLinking":null,"ep":"9","iss":null,"sp":"1","vol":null,"edition":null,"conferencePlace":null,"conferenceDate":null},"documentationUrls":null,"codeRepositoryUrl":null,"programmingLanguage":null,"contactPeople":null,"contactGroups":null,"tools":null,"size":null,"version":null,"geoLocations":null,"id":"doi_dedup___::e90cf1a8f0350b75ad97b48605eda9b8","originalIds":["10.9734/jerr/2019/v4i116895","50|doiboost____|e90cf1a8f0350b75ad97b48605eda9b8","2960727233"],"pids":[{"scheme":"doi","value":"10.9734/jerr/2019/v4i116895"}],"dateOfCollection":null,"lastUpdateTimeStamp":null,"indicators":{"citationImpact":{"citationCount":1,"influence":2.637793e-9,"popularity":2.0705595e-9,"impulse":1,"citationClass":"C5","influenceClass":"C5","impulseClass":"C5","popularityClass":"C5"}},"instances":[{"pids":[{"scheme":"doi","value":"10.9734/jerr/2019/v4i116895"}],"type":"Article","urls":["https://doi.org/10.9734/jerr/2019/v4i116895"],"publicationDate":"2019-03-12","refereed":"peerReviewed"},{"pids":[{"scheme":"doi","value":"10.9734/jerr/2019/v4i116895"}],"type":"Article","urls":["https://doi.org/10.9734/jerr/2019/v4i116895"],"refereed":"nonPeerReviewed"},{"alternateIdentifiers":[{"scheme":"doi","value":"10.9734/jerr/2019/v4i116895"},{"scheme":"mag_id","value":"2960727233"}],"type":"Other literature type","urls":["https://dx.doi.org/10.9734/jerr/2019/v4i116895"],"refereed":"nonPeerReviewed"}],"isGreen":false,"isInDiamondJournal":false}
local.import.sourceOpenAire

Dosyalar

Koleksiyonlar