Yayın:
The energy spectrum of 662keV photons in a water equivalent phantom

dc.contributor.authorAkar Tarim, U.
dc.contributor.authorGurler, O.
dc.contributor.authorOzmutlu, En
dc.contributor.authorYalcin, S.
dc.contributor.authorGundogdu, O.
dc.contributor.authorSharaf, Jm
dc.contributor.authorBradley, Da
dc.date.accessioned2026-01-02T20:08:29Z
dc.date.issued2012-07-01
dc.description.abstractInvestigation is made on the energy spectrum of photons originating from interactions of 662 keV primary gamma-ray photons emitted by a point source positioned at the centre of a water equivalent solid phantom of dimensions 19 cm×19 cm×24 cm. Peaks resulting from total energy loss (photopeak) and multiple and back scattering have been observed using a 51 mm×51 mm NaI(Tl) detector; good agreement being found between the measured and simulated response functions. The energy spectrum of the gamma photons obtained through the Monte Carlo simulation reveals local maxima at about 100 keV and 210 keV, being also observed in the experimental response function. Such spectra can be used as a method of testing the water equivalence of solid phantom media before their use for dosimetry measurements.
dc.description.urihttps://doi.org/10.1016/j.radphyschem.2012.03.019
dc.description.urihttps://dx.doi.org/10.1016/j.radphyschem.2012.03.019
dc.description.urihttps://avesis.kocaeli.edu.tr/publication/details/56cef22e-0fee-4048-8b00-32e80c58e02d/oai
dc.description.urihttps://avesis.uludag.edu.tr/publication/details/56cef22e-0fee-4048-8b00-32e80c58e02d/oai
dc.description.urihttps://doi.org/https://doi.org/10.1016/j.radphyschem.2012.03.019
dc.identifier.doi10.1016/j.radphyschem.2012.03.019
dc.identifier.endpage748
dc.identifier.issn0969-806X
dc.identifier.openairedoi_dedup___::dec52139184c91851775910dc593832d
dc.identifier.orcid0000-0001-6779-9230
dc.identifier.orcid0000-0003-0171-3179
dc.identifier.scopus2-s2.0-84861660959
dc.identifier.startpage745
dc.identifier.urihttps://hdl.handle.net/20.500.12597/35604
dc.identifier.volume81
dc.identifier.wos000305656800005
dc.language.isoeng
dc.publisherElsevier BV
dc.relation.ispartofRadiation Physics and Chemistry
dc.rightsCLOSED
dc.subject.sdg7. Clean energy
dc.titleThe energy spectrum of 662keV photons in a water equivalent phantom
dc.typeArticle
dspace.entity.typePublication
local.api.response{"authors":[{"fullName":"Akar Tarim, U","name":"U.","surname":"Akar Tarim","rank":1,"pid":null},{"fullName":"Gurler, O","name":"O.","surname":"Gurler","rank":2,"pid":null},{"fullName":"Ozmutlu, EN","name":"En","surname":"Ozmutlu","rank":3,"pid":null},{"fullName":"Yalcin, S","name":"S.","surname":"Yalcin","rank":4,"pid":{"id":{"scheme":"orcid","value":"0000-0001-6779-9230"},"provenance":null}},{"fullName":"Gundogdu, O","name":"O.","surname":"Gundogdu","rank":5,"pid":{"id":{"scheme":"orcid","value":"0000-0003-0171-3179"},"provenance":null}},{"fullName":"Sharaf, JM","name":"Jm","surname":"Sharaf","rank":6,"pid":null},{"fullName":"Bradley, DA","name":"Da","surname":"Bradley","rank":7,"pid":null}],"openAccessColor":null,"publiclyFunded":false,"type":"publication","language":{"code":"eng","label":"English"},"countries":null,"subjects":[{"subject":{"scheme":"FOS","value":"03 medical and health sciences"},"provenance":null},{"subject":{"scheme":"FOS","value":"0302 clinical medicine"},"provenance":null},{"subject":{"scheme":"SDG","value":"7. Clean energy"},"provenance":null}],"mainTitle":"The energy spectrum of 662keV photons in a water equivalent phantom","subTitle":null,"descriptions":["Investigation is made on the energy spectrum of photons originating from interactions of 662 keV primary gamma-ray photons emitted by a point source positioned at the centre of a water equivalent solid phantom of dimensions 19 cm×19 cm×24 cm. Peaks resulting from total energy loss (photopeak) and multiple and back scattering have been observed using a 51 mm×51 mm NaI(Tl) detector; good agreement being found between the measured and simulated response functions. The energy spectrum of the gamma photons obtained through the Monte Carlo simulation reveals local maxima at about 100 keV and 210 keV, being also observed in the experimental response function. Such spectra can be used as a method of testing the water equivalence of solid phantom media before their use for dosimetry measurements."],"publicationDate":"2012-07-01","publisher":"Elsevier BV","embargoEndDate":null,"sources":["Crossref"],"formats":null,"contributors":null,"coverages":null,"bestAccessRight":{"code":"c_14cb","label":"CLOSED","scheme":"http://vocabularies.coar-repositories.org/documentation/access_rights/"},"container":{"name":"Radiation Physics and Chemistry","issnPrinted":"0969-806X","issnOnline":null,"issnLinking":null,"ep":"748","iss":null,"sp":"745","vol":"81","edition":null,"conferencePlace":null,"conferenceDate":null},"documentationUrls":null,"codeRepositoryUrl":null,"programmingLanguage":null,"contactPeople":null,"contactGroups":null,"tools":null,"size":null,"version":null,"geoLocations":null,"id":"doi_dedup___::dec52139184c91851775910dc593832d","originalIds":["S0969806X12001673","10.1016/j.radphyschem.2012.03.019","50|doiboost____|dec52139184c91851775910dc593832d","2056162286","50|od_____10011::8a5d4588bfb4fcc89db95eea833ec15b","56cef22e-0fee-4048-8b00-32e80c58e02d","50|od______9458::8a5d4588bfb4fcc89db95eea833ec15b","50|base_oa_____::88660917d4a048802ab931663310d286","ftusurrey:oai:epubs.surrey.ac.uk:835183"],"pids":[{"scheme":"doi","value":"10.1016/j.radphyschem.2012.03.019"}],"dateOfCollection":null,"lastUpdateTimeStamp":null,"indicators":{"citationImpact":{"citationCount":6,"influence":3.4064076e-9,"popularity":1.614352e-9,"impulse":3,"citationClass":"C5","influenceClass":"C4","impulseClass":"C5","popularityClass":"C5"}},"instances":[{"pids":[{"scheme":"doi","value":"10.1016/j.radphyschem.2012.03.019"}],"license":"Elsevier TDM","type":"Article","urls":["https://doi.org/10.1016/j.radphyschem.2012.03.019"],"publicationDate":"2012-07-01","refereed":"peerReviewed"},{"alternateIdentifiers":[{"scheme":"doi","value":"10.1016/j.radphyschem.2012.03.019"},{"scheme":"mag_id","value":"2056162286"}],"type":"Article","urls":["https://dx.doi.org/10.1016/j.radphyschem.2012.03.019"],"refereed":"nonPeerReviewed"},{"alternateIdentifiers":[{"scheme":"doi","value":"10.1016/j.radphyschem.2012.03.019"}],"type":"Article","urls":["https://avesis.kocaeli.edu.tr/publication/details/56cef22e-0fee-4048-8b00-32e80c58e02d/oai"],"publicationDate":"2012-07-01","refereed":"nonPeerReviewed"},{"alternateIdentifiers":[{"scheme":"doi","value":"10.1016/j.radphyschem.2012.03.019"}],"type":"Article","urls":["https://avesis.uludag.edu.tr/publication/details/56cef22e-0fee-4048-8b00-32e80c58e02d/oai"],"publicationDate":"2012-07-01","refereed":"nonPeerReviewed"},{"alternateIdentifiers":[{"scheme":"doi","value":"10.1016/j.radphyschem.2012.03.019"}],"type":"Article","urls":["https://doi.org/https://doi.org/10.1016/j.radphyschem.2012.03.019"],"publicationDate":"2012-07-01","refereed":"nonPeerReviewed"}],"isGreen":false,"isInDiamondJournal":false}
local.import.sourceOpenAire
local.indexed.atWOS
local.indexed.atScopus

Dosyalar

Koleksiyonlar