Browsing by Author "Alkhaled W.H."
Now showing 1 - 2 of 2
- Results Per Page
- Sort Options
Scopus A new approach to develop biometric fingerprint using human right thumb fingernail(2023-07-01) Al-Sultan T.G.; Abduljabar A.Q.; Alkhaled W.H.; Al-Sawaff Z.H.; Kandemirli F.In this article, we analyzed the structure of human nails to develop a modern biometric authentication system based on the nail bed and finger lunula. The results of the studies on the collected images proved that each fingernail has distinctive characteristics in terms of the length and width of the nail and the lunula, even identical twins. We focused on the fingernail of the right thumb because of its large size and the accuracy and clarity of the nail. The mediation of the indicative points on the nail bed and on the lunula was used to form the pentagonal structure and use it as a region of interest. Then an ensemble independent component analysis, principal component analysis, haar wavelet, and scale invariant feature transformation, were used. Later we classified these algorithms using support vector machine and Naive Bayes techniques, the performance of each algorithm was analyzed by feature extraction with two classifiers. This study was conducted on 100 participants and showed that this new method could be used as a biometric identification system for humans. There was no similarity in results for all verified samples.Scopus Design of an orthopedic smart splint using nickel-titanium shape memory alloy(2023-03-01) Alhialy A.; Alkhaled W.H.; Al-Sultan T.G.; Al-Sawaff Z.H.; Kandimerli F.People with broken bones suffer from symptoms of muscular atrophy as a result of a lack of movement, so it was necessary to find effective solutions due to the relative pain they cause and the difficulty of movement after healing. In this paper, we proposed a smart splint made of nickel-titanium shape memory alloys (SMA) wires. These alloys have unique properties compared to other materials, the most important of which is maintaining the original shape during manufacturing at a certain temperature. Temperature, pressure, as well as humidity, were analyzed and monitored while the patient wore the splint to reach the best possible results by using a microcontroller. The results showed that there was a significant improvement for the muscles in a short time when using the proposed splint, as the percentage of qualified muscle recovery increased by more than 70% when using the usual splint. The wires used had an effective role in rehabilitating these muscles by performing a permanent local massage. due to the different diameters of these wires, a different response to temperature change was recorded.