Yayın: Ultrasonographic and macroscopic comparison of the thickness of the capsule, corium, and soft tissues in bovine claws: anin vitrostudy
| dc.contributor.author | Cecen, Goksen | |
| dc.contributor.author | Salci, Hakan | |
| dc.contributor.author | Intas, Deniz Seyrek | |
| dc.contributor.author | Celimli, Nureddin | |
| dc.contributor.author | Caliskan, Gulsum Ulke | |
| dc.date.accessioned | 2026-01-02T23:18:58Z | |
| dc.date.issued | 2015-01-01 | |
| dc.description.abstract | This study aimed to compare thickness of the capsule, corium, and soft tissues measured ultrasonographically and macroscopically in selected regions of bovine claws. A hundred and twenty claws (n = 120) of 15 healthy Holstein bovines were obtained. After cleaning the claws, ultrasonographic measurement of the capsule, corium, and soft tissues was performed while submerging the claws in a water bath. Macroscopic measurements were taken after cutting of the claws axially. These values were compared statistically. According to the macroscopic measurements, the mean thickness ± standard deviation (SD) of the capsule for dorsal wall and sole was 6.2 ± 0.1 and 9.5 ± 0.4 mm, respectively. The thickness of the corium and soft tissues for dorsal wall and sole was 4.5 ± 0.1 and 5.3 ± 0.1 mm, respectively. Ultrasonographically, the mean thickness ± SD of the capsule for dorsal wall and sole was 4.7 ± 0.1 and 7.8 ± 0.3 mm, respectively. The thickness of the corium and soft tissues for dorsal wall and sole was 4.3 ± 0.1 and 5.9 ± 0.2 mm, respectively. Findings demonstrated that ultrasonography can be reliably to measure of the thickness of the hoof capsule, corium, and soft tissue in bovine claw. | |
| dc.description.uri | https://doi.org/10.4142/jvs.2015.16.1.107 | |
| dc.description.uri | https://pubmed.ncbi.nlm.nih.gov/25269721 | |
| dc.description.uri | http://dx.doi.org/10.4142/jvs.2015.16.1.107 | |
| dc.description.uri | https://dx.doi.org/10.4142/jvs.2015.16.1.107 | |
| dc.description.uri | https://avesis.uludag.edu.tr/publication/details/1e3a0304-e2b2-4b11-a40f-82e77962eeec/oai | |
| dc.description.uri | https://aperta.ulakbim.gov.tr/record/77593 | |
| dc.identifier.doi | 10.4142/jvs.2015.16.1.107 | |
| dc.identifier.eissn | 1976-555X | |
| dc.identifier.issn | 1229-845X | |
| dc.identifier.openaire | doi_dedup___::c20d0661163250e03fc78b7ca56a3ee3 | |
| dc.identifier.orcid | 0000-0001-8537-0761 | |
| dc.identifier.orcid | 0000-0002-4542-315x | |
| dc.identifier.pubmed | 25269721 | |
| dc.identifier.scopus | 2-s2.0-84928538296 | |
| dc.identifier.startpage | 107 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.12597/35933 | |
| dc.identifier.volume | 16 | |
| dc.identifier.wos | 000351480900014 | |
| dc.language.iso | eng | |
| dc.publisher | The Korean Society of Veterinary Science | |
| dc.relation.ispartof | Journal of Veterinary Science | |
| dc.rights | OPEN | |
| dc.subject | Hoof and Claw | |
| dc.subject | Cadaver | |
| dc.subject | Animals | |
| dc.subject | Original Article | |
| dc.subject | Cattle | |
| dc.subject | Ultrasonography | |
| dc.title | Ultrasonographic and macroscopic comparison of the thickness of the capsule, corium, and soft tissues in bovine claws: anin vitrostudy | |
| dc.type | Article | |
| dspace.entity.type | Publication | |
| local.import.source | OpenAire | |
| local.indexed.at | WOS | |
| local.indexed.at | Scopus | |
| local.indexed.at | PubMed |
