Determination of pumper truck intervention ratios in zones with high fire potential by using geographical information system

dc.contributor.authorAricak, Burak
dc.contributor.authorKucuk, Omer
dc.contributor.authorEnez, Korhan
dc.date.accessioned2026-01-02T23:10:51Z
dc.date.issued2014-06-16
dc.description.abstractFighting forest fires not only depends on the forest type, topography, and weather conditions, but is also closely related to the technical properties of fire-fighting equipment. Firefighting is an important part of fire management planning. However, because of the complex nature of forests, creating thematic layers to generate potential fire risk maps is difficult. The use of remote sensing data has become an efficient method for the discrete classification of potential fire risks. The study was located in the Central District of the Kastamonu Regional Forest Directorate, covering an area of 24,320 ha, 15,685 ha of which is forested. On the basis of stand age, crown closure, and tree species, the sizes and distributions of potential fire risk zones within the study area were determined using high-resolution GeoEye satellite imagery and geographical information system data. The status of pumper truck intervention in zones with high fire risk and the sufficiency of existing forest roads within an existing forest network were discussed based on combustible matter characteristics. Pumper truck intervention was 83% for high-risk zones, 79% for medium-risk zones, and 78% for low-risk zones. A pumper truck intervention area map along existing roads was also created.
dc.description.urihttps://doi.org/10.1117/1.jrs.8.083598
dc.description.urihttps://www.spiedigitallibrary.org/journals/Journal-of-Applied-Remote-Sensing/volume-8/issue-1/083598/Determination-of-pumper-truck-intervention-ratios-in-zones-with-high/10.1117/1.JRS.8.083598.pdf
dc.description.urihttps://dx.doi.org/10.1117/1.jrs.8.083598
dc.description.urihttps://aperta.ulakbim.gov.tr/record/67041
dc.identifier.doi10.1117/1.jrs.8.083598
dc.identifier.issn1931-3195
dc.identifier.openairedoi_dedup___::6612206b5eb423fe83fa243270793bd8
dc.identifier.orcid0000-0003-0011-7199
dc.identifier.scopus2-s2.0-84905728202
dc.identifier.startpage083598
dc.identifier.urihttps://hdl.handle.net/20.500.12597/35840
dc.identifier.volume8
dc.identifier.wos000338499700001
dc.language.isoeng
dc.publisherSPIE-Intl Soc Optical Eng
dc.relation.ispartofJournal of Applied Remote Sensing
dc.rightsOPEN
dc.subject.sdg13. Climate action
dc.subject.sdg11. Sustainability
dc.subject.sdg15. Life on land
dc.titleDetermination of pumper truck intervention ratios in zones with high fire potential by using geographical information system
dc.typeArticle
dspace.entity.typePublication
local.api.response{"authors":[{"fullName":"Aricak, Burak","name":"Burak","surname":"Aricak","rank":1,"pid":{"id":{"scheme":"orcid","value":"0000-0003-0011-7199"},"provenance":null}},{"fullName":"Kucuk, Omer","name":"Omer","surname":"Kucuk","rank":2,"pid":null},{"fullName":"Enez, Korhan","name":"Korhan","surname":"Enez","rank":3,"pid":null}],"openAccessColor":"hybrid","publiclyFunded":false,"type":"publication","language":{"code":"eng","label":"English"},"countries":null,"subjects":[{"subject":{"scheme":"SDG","value":"13. Climate action"},"provenance":null},{"subject":{"scheme":"SDG","value":"11. Sustainability"},"provenance":null},{"subject":{"scheme":"SDG","value":"15. Life on land"},"provenance":null},{"subject":{"scheme":"FOS","value":"01 natural sciences"},"provenance":null},{"subject":{"scheme":"FOS","value":"0105 earth and related environmental sciences"},"provenance":null}],"mainTitle":"Determination of pumper truck intervention ratios in zones with high fire potential by using geographical information system","subTitle":null,"descriptions":["Fighting forest fires not only depends on the forest type, topography, and weather conditions, but is also closely related to the technical properties of fire-fighting equipment. Firefighting is an important part of fire management planning. However, because of the complex nature of forests, creating thematic layers to generate potential fire risk maps is difficult. The use of remote sensing data has become an efficient method for the discrete classification of potential fire risks. The study was located in the Central District of the Kastamonu Regional Forest Directorate, covering an area of 24,320 ha, 15,685 ha of which is forested. On the basis of stand age, crown closure, and tree species, the sizes and distributions of potential fire risk zones within the study area were determined using high-resolution GeoEye satellite imagery and geographical information system data. The status of pumper truck intervention in zones with high fire risk and the sufficiency of existing forest roads within an existing forest network were discussed based on combustible matter characteristics. Pumper truck intervention was 83% for high-risk zones, 79% for medium-risk zones, and 78% for low-risk zones. A pumper truck intervention area map along existing roads was also created."],"publicationDate":"2014-06-16","publisher":"SPIE-Intl Soc Optical Eng","embargoEndDate":null,"sources":["Crossref"],"formats":null,"contributors":null,"coverages":null,"bestAccessRight":{"code":"c_abf2","label":"OPEN","scheme":"http://vocabularies.coar-repositories.org/documentation/access_rights/"},"container":{"name":"Journal of Applied Remote Sensing","issnPrinted":"1931-3195","issnOnline":null,"issnLinking":null,"ep":null,"iss":null,"sp":"083598","vol":"8","edition":null,"conferencePlace":null,"conferenceDate":null},"documentationUrls":null,"codeRepositoryUrl":null,"programmingLanguage":null,"contactPeople":null,"contactGroups":null,"tools":null,"size":null,"version":null,"geoLocations":null,"id":"doi_dedup___::6612206b5eb423fe83fa243270793bd8","originalIds":["10.1117/1.jrs.8.083598","50|doiboost____|6612206b5eb423fe83fa243270793bd8","2157145330","50|r39c86a4b39b::c9e5a8644f40a0f1d0bbe4ffde5610e5","oai:zenodo.org:67041"],"pids":[{"scheme":"doi","value":"10.1117/1.jrs.8.083598"}],"dateOfCollection":null,"lastUpdateTimeStamp":null,"indicators":{"citationImpact":{"citationCount":7,"influence":3.772205e-9,"popularity":4.2392827e-9,"impulse":4,"citationClass":"C5","influenceClass":"C4","impulseClass":"C5","popularityClass":"C4"}},"instances":[{"pids":[{"scheme":"doi","value":"10.1117/1.jrs.8.083598"}],"type":"Article","urls":["https://doi.org/10.1117/1.jrs.8.083598"],"publicationDate":"2014-06-16","refereed":"peerReviewed"},{"pids":[{"scheme":"doi","value":"10.1117/1.jrs.8.083598"}],"license":"CC BY","type":"Article","urls":["https://www.spiedigitallibrary.org/journals/Journal-of-Applied-Remote-Sensing/volume-8/issue-1/083598/Determination-of-pumper-truck-intervention-ratios-in-zones-with-high/10.1117/1.JRS.8.083598.pdf"],"refereed":"nonPeerReviewed"},{"alternateIdentifiers":[{"scheme":"doi","value":"10.1117/1.jrs.8.083598"},{"scheme":"mag_id","value":"2157145330"}],"type":"Article","urls":["https://dx.doi.org/10.1117/1.jrs.8.083598"],"refereed":"nonPeerReviewed"},{"license":"CC BY","type":"Other literature type","urls":["https://aperta.ulakbim.gov.tr/record/67041"],"publicationDate":"2014-01-01","refereed":"nonPeerReviewed"}],"isGreen":true,"isInDiamondJournal":false}