Yayın:
Evaluation of the relationship between digital mammography radiation dose and patient age, breast volume and density

dc.contributor.authorECE, Bünyamin
dc.date.accessioned2026-01-04T19:14:07Z
dc.date.issued2023-09-28
dc.description.abstractAims: To determine the average radiation dose values in patients who underwent routine screening mammography in our hospital, establish the relationship between breast density and volume, and investigate other factors affecting radiation dose. Methods: Screening bilateral mammography was retrospectively evaluated within the specified period of 2 months. Patient age, breast density ratio, mammographic size of the breast, calculated breast volume, tube voltage, current, exposure time (ms), compression force (kg), compression thickness (mm), and radiation dose (mGy) given in each projection were recorded separately for each patient. According to the BI-RADS, breast densities classified as types A-B were considered non-dense, while types C-D were considered dense breasts. The 75th percentile dose value (mGy) was chosen as the cutoff for high dose group. Logistic regression analyses were used to examine the factors affecting radiation dose. Results: 1720 mammograms from 430 patients were studied. 276 (64.2%) breasts were non-dense, while 154 (35.8%) breasts were dense. The mean total breast volume was 595±334 ml, compression thickness was 36.5±12.0 mm, and radiation dose was 2.04±0.75 mGy. There was a negative correlation between radiation dose and age (r=-0.330, p
dc.description.urihttps://doi.org/10.32322/jhsm.1340385
dc.description.urihttps://dergipark.org.tr/tr/pub/jhsm/issue/80018/1340385
dc.identifier.doi10.32322/jhsm.1340385
dc.identifier.eissn2636-8579
dc.identifier.endpage961
dc.identifier.openairedoi_dedup___::feff27d8670a64ae388bf1b24fee9c9f
dc.identifier.orcid0000-0001-6288-8410
dc.identifier.startpage954
dc.identifier.urihttps://hdl.handle.net/20.500.12597/41059
dc.identifier.volume6
dc.language.isoeng
dc.publisherJournal of Health Sciences and Medicine
dc.relation.ispartofJournal of Health Sciences and Medicine
dc.rightsOPEN
dc.subjectMammography
dc.subjectbreast
dc.subjectradiation dosage
dc.subjectdiagnostic imaging
dc.subjectbreast density
dc.subjectdiagnostic screening programs
dc.subjectRadyoloji ve Organ Görüntüleme
dc.subjectRadiology and Organ Imaging
dc.subject.sdg3. Good health
dc.titleEvaluation of the relationship between digital mammography radiation dose and patient age, breast volume and density
dc.typeArticle
dspace.entity.typePublication
local.api.response{"authors":[{"fullName":"Bünyamin ECE","name":"Bünyamin","surname":"ECE","rank":1,"pid":{"id":{"scheme":"orcid","value":"0000-0001-6288-8410"},"provenance":null}}],"openAccessColor":"gold","publiclyFunded":false,"type":"publication","language":{"code":"eng","label":"English"},"countries":null,"subjects":[{"subject":{"scheme":"FOS","value":"03 medical and health sciences"},"provenance":null},{"subject":{"scheme":"keyword","value":"Mammography;breast;radiation dosage;diagnostic imaging;breast density;diagnostic screening programs"},"provenance":null},{"subject":{"scheme":"FOS","value":"0302 clinical medicine"},"provenance":null},{"subject":{"scheme":"keyword","value":"Radyoloji ve Organ Görüntüleme"},"provenance":null},{"subject":{"scheme":"keyword","value":"Radiology and Organ Imaging"},"provenance":null},{"subject":{"scheme":"SDG","value":"3. Good health"},"provenance":null}],"mainTitle":"Evaluation of the relationship between digital mammography radiation dose and patient age, breast volume and density","subTitle":null,"descriptions":["<jats:p xml:lang=\"en\">Aims: To determine the average radiation dose values in patients who underwent routine screening mammography in our hospital, establish the relationship between breast density and volume, and investigate other factors affecting radiation dose. Methods: Screening bilateral mammography was retrospectively evaluated within the specified period of 2 months. Patient age, breast density ratio, mammographic size of the breast, calculated breast volume, tube voltage, current, exposure time (ms), compression force (kg), compression thickness (mm), and radiation dose (mGy) given in each projection were recorded separately for each patient. According to the BI-RADS, breast densities classified as types A-B were considered non-dense, while types C-D were considered dense breasts. The 75th percentile dose value (mGy) was chosen as the cutoff for high dose group. Logistic regression analyses were used to examine the factors affecting radiation dose. Results: 1720 mammograms from 430 patients were studied. 276 (64.2%) breasts were non-dense, while 154 (35.8%) breasts were dense. The mean total breast volume was 595±334 ml, compression thickness was 36.5±12.0 mm, and radiation dose was 2.04±0.75 mGy. There was a negative correlation between radiation dose and age (r=-0.330, p</jats:p>"],"publicationDate":"2023-09-28","publisher":"Journal of Health Sciences and Medicine","embargoEndDate":null,"sources":["Crossref","Volume: 6, Issue: 5 954-961","2636-8579","Journal of Health Sciences and Medicine"],"formats":["application/pdf"],"contributors":null,"coverages":null,"bestAccessRight":{"code":"c_abf2","label":"OPEN","scheme":"http://vocabularies.coar-repositories.org/documentation/access_rights/"},"container":{"name":"Journal of Health Sciences and Medicine","issnPrinted":null,"issnOnline":"2636-8579","issnLinking":null,"ep":"961","iss":null,"sp":"954","vol":"6","edition":null,"conferencePlace":null,"conferenceDate":null},"documentationUrls":null,"codeRepositoryUrl":null,"programmingLanguage":null,"contactPeople":null,"contactGroups":null,"tools":null,"size":null,"version":null,"geoLocations":null,"id":"doi_dedup___::feff27d8670a64ae388bf1b24fee9c9f","originalIds":["10.32322/jhsm.1340385","50|doiboost____|feff27d8670a64ae388bf1b24fee9c9f","oai:dergipark.org.tr:article/1340385","50|tubitakulakb::bb88c3f2e6a1aee42181e08d2717dbc9"],"pids":[{"scheme":"doi","value":"10.32322/jhsm.1340385"}],"dateOfCollection":null,"lastUpdateTimeStamp":null,"indicators":{"citationImpact":{"citationCount":0,"influence":2.5349236e-9,"popularity":2.1399287e-9,"impulse":0,"citationClass":"C5","influenceClass":"C5","impulseClass":"C5","popularityClass":"C5"}},"instances":[{"pids":[{"scheme":"doi","value":"10.32322/jhsm.1340385"}],"type":"Article","urls":["https://doi.org/10.32322/jhsm.1340385"],"publicationDate":"2023-09-28","refereed":"peerReviewed"},{"alternateIdentifiers":[{"scheme":"doi","value":"10.32322/jhsm.1340385"}],"type":"Article","urls":["https://dergipark.org.tr/tr/pub/jhsm/issue/80018/1340385"],"publicationDate":"2023-08-09","refereed":"nonPeerReviewed"}],"isGreen":false,"isInDiamondJournal":false}