Publication:
Effect of Timber Type and Nail Spacing on the Hysteretic Behavior of Timber-Framed Shear Walls with Openings

dc.contributor.authorAnil Ö., Togay A., Karagöz Işleyen Ü., Döngel N., Stlü C.
dc.contributor.authorAnil, O, Togay, A, Isleyen, UK, Dongel, N, Sogutlu, C
dc.date.accessioned2023-05-09T15:54:13Z
dc.date.available2023-05-09T15:54:13Z
dc.date.issued2018-06-01
dc.date.issued2018.01.01
dc.description.abstractIn scope of the study, behavior of timber-framed shear walls having openings with variable dimensions and locations subjected to reverse cyclic loading is experimentally investigated. Main variables considered in the study are the aspect ratios of timber-framed panel walls, dimensions and locations of the openings on the panel walls, material of the timber frames and spacings of the nails used in the panel connections. Load–displacement relationships, strengths, stiffnesses, displacement ductility ratios, energy dissipation capacities and failure mechanisms of the specimens are determined. The ultimate load capacities of the timber-framed panels are calculated as per Eurocode 5 and presented in comparison to experimental results. Moreover, lateral load-resisting capacities and load–displacement relationships of the test specimens are numerically calculated with finite element analyses. A good agreement was observed between the numerical and experimental results. From the test results, it is observed that the load behavior relationships of the test specimens significantly affected by aspect ratios, location of the openings, material of the timber frames and spacing of the nails used to provide connection between the timber-framed panel elements. Also, the increasing size of the openings decreased the stiffness’ of the test specimens.
dc.identifier.doi10.1007/s40999-016-0138-7
dc.identifier.eissn2383-3874
dc.identifier.endpage646
dc.identifier.issn1735-0522
dc.identifier.scopus2-s2.0-85047492255
dc.identifier.startpage629
dc.identifier.urihttps://hdl.handle.net/20.500.12597/12721
dc.identifier.volume16
dc.identifier.wosWOS:000433050000004
dc.relation.ispartofInternational Journal of Civil Engineering
dc.relation.ispartofINTERNATIONAL JOURNAL OF CIVIL ENGINEERING
dc.rightsfalse
dc.subjectCyclic load | Finite element analysis | Hysteretic behavior | Opening | Timber-framed shear wall
dc.titleEffect of Timber Type and Nail Spacing on the Hysteretic Behavior of Timber-Framed Shear Walls with Openings
dc.titleEffect of Timber Type and Nail Spacing on the Hysteretic Behavior of Timber-Framed Shear Walls with Openings
dc.typeArticle
dspace.entity.typePublication
oaire.citation.issue6
oaire.citation.volume16
relation.isScopusOfPublication4bc9f6fc-67d4-421a-90b3-292c032a6238
relation.isScopusOfPublication.latestForDiscovery4bc9f6fc-67d4-421a-90b3-292c032a6238
relation.isWosOfPublication3e881089-2edd-47a7-9a1e-4c40e7e41e6c
relation.isWosOfPublication.latestForDiscovery3e881089-2edd-47a7-9a1e-4c40e7e41e6c

Files

Collections